{"product_id":"honeywell-mc-taih03-51309136-175-analog-input-module","title":"Honeywell MC-TAIH03 51309136-175 Analog Input Module","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eConfigured for high-level analog signal processing in Honeywell Experion LX networks, the \u003cstrong\u003eHoneywell MC-TAIH03 51309136-175\u003c\/strong\u003e (\u003cstrong\u003eMC-TAIH03\u003c\/strong\u003e High-Level Analog Input Field Termination Assembly) provides direct physical\/electrical execution. It interfaces 16 field transmitter loops directly to process controllers via standard current and voltage conversion circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH03 (Part Number: 51309136-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm x 80 mm x 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 24 VDC external loop supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA or 0-10 V (Input Voltage Range: +\/-10 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion LX DCS \/ Universal Control Network (UCN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MC-TAIH03 termination assembly conditions 16 high-level 4-20 mA and 0-10 V analog input signals before routing digitization data to system I\/O processors. High input impedance across each channel minimizes signal loading effects on transmitter loops. Integrated channel-to-channel isolation and surge suppression circuits isolate individual field wiring runs, preventing ground loop currents and high-frequency common-mode noise from corrupting adjacent signal paths or disrupting HART loop communication overlay protocols.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input signal ranges can be wired directly to the MC-TAIH03 termination assembly terminals?\u003c\/p\u003e\n\u003cp\u003eA: The terminal assembly accepts standard 4-20 mA process loop currents as well as 0-10 V (or +\/-10 VDC range) high-level analog voltage inputs across its 16 channels.\u003c\/p\u003e\n\u003cp\u003eQ: How does the MC-TAIH03 protect the DCS I\/O processing hardware from field-side electrical interference?\u003c\/p\u003e\n\u003cp\u003eA: The assembly incorporates isolation and filtering networks that block high-voltage transients and eliminate common-mode ground noise between field transmitter loops and system input cards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the MC-TAIH03 assembly securely onto the cabinet DIN rail or carrier base, ensuring a low-impedance connection to the local protective earthing bar.\u003c\/li\u003e\n\u003cli\u003eTerminate 4-20 mA and 0-10 V field wiring securely at the screw terminal connectors, observing correct polarity for each of the 16 channels.\u003c\/li\u003e\n\u003cli\u003eKeep field analog signal cabling routed in dedicated, shielded wire ducts separate from high-voltage AC distribution or motor power lines.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52608876118296,"sku":"MC-TAIH03 51309136-175","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/CC-TUIO11.png?v=1788426787","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-mc-taih03-51309136-175-analog-input-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}