{"product_id":"honeywell-mc-pdox02-digital-output-processor","title":"Honeywell MC-PDOX02 Digital Output Processor","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cp\u003eConfigured for digital output execution in Honeywell Process Manager platforms, the \u003cstrong\u003eHoneywell 51304487-150\u003c\/strong\u003e (\u003cstrong\u003eMC-PDOX02\u003c\/strong\u003e Digital Output Processor) provides direct physical\/electrical execution for 16 discrete channels across industrial process control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-PDOX02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg (4.41 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard High-Performance Process Manager I\/O Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304487-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 Output Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output (DO) Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Compliance\u003c\/td\u003e\n\u003ctd\u003eCompliant (51304487-150)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformally Coated Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ Experion PKS High-Performance Process Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; DCS Output Loop Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MC-PDOX02 digital output processor incorporates optical channel-to-channel isolation barriers to decouple internal control logic from external field switching surges. Operating within DCS field termination assemblies, each discrete channel supports direct switching of inductive loads while maintaining fast loop feedback response. Conformal coating applied across the printed circuit assembly protects active components against chemical gas exposure and high humidity levels. The integrated logic circuits interface directly with 4-20 mA HART loop protocol subsystem cards and process manager I\/O buses to enforce continuous output state verification without introducing cross-channel noise into neighboring I\/O cards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What protection does the conformal coating on part number 51304487-150 provide in industrial field environments?\u003c\/p\u003e\n\u003cp\u003eA: The conformal coating applies a thin protective polymer layer over all surface-mount circuitry, shielding sensitive electronic paths from atmospheric moisture, airborne sulfur, and corrosive gaseous contaminants.\u003c\/p\u003e\n\u003cp\u003eQ: Is the MC-PDOX02 digital output card rated for hot-swapping inside a live Process Manager file?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports live insertion and removal within the card chassis under power, provided proper grounding practices are observed and system redundancy limits are maintained during card extraction.\u003c\/p\u003e\n\u003cp\u003eQ: How many discrete output channels does a single MC-PDOX02 processor board drive?\u003c\/p\u003e\n\u003cp\u003eA: A single MC-PDOX02 processor handles 16 discrete digital output channels, communicating status directly to the High-Performance Process Manager backplane bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the MC-PDOX02 into an available slot within the Process Manager I\/O card rack, ensuring side card guides line up prior to fully seating the backplane edge connector. Verify that ESD grounding straps are worn during physical handling to prevent static discharge to the conformally coated assembly.\u003c\/p\u003e\n\u003cp\u003eField wiring connections must terminate at the corresponding Field Termination Assembly (FTA) using shielded twisted-pair cables. Route discrete power circuits away from low-level analog input lines within panel wireways to minimize inductive interference. Maintain panel grounding connection impedance to main earth at less than 1 ohm.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52836503027992,"sku":"MC-PDOX02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/51304485-150_Cocoai_2d19a438-4c6e-4c7a-9992-210a75eae8c4.jpg?v=1791511587","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-mc-pdox02-digital-output-processor","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}