{"product_id":"honeywell-fs-tsdo-0824-safe-digital-output-module","title":"Honeywell FS-TSDO-0824 Safe Digital Output Module","description":"\u003cp\u003eConfigured for safety-critical actuator and solenoid control in Safety Manager platforms, the \u003cstrong\u003eHoneywell FS-TSDO-0824\u003c\/strong\u003e (\u003cstrong\u003eFS-TSDO-0824\u003c\/strong\u003e safe digital output module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-TSDO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard safety module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCabinet installation form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Fault-Tolerant Execution\u003c\/h3\u003e\n\u003cp\u003eThe module implements strict channel-to-channel isolation and system-level galvanic barriers to eliminate ground loops and prevent common-mode noise propagation across safety-critical actuator loops. Internal supervision circuits continuously monitor load current continuity and switch state health, executing fail-safe state responses immediately if open-circuit, short-circuit, or power supply deviation anomalies are detected.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum continuous output current rating per channel?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 8 isolated digital output channels delivers up to 0.5 A of continuous output current at 24 VDC nominal supply.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swapping under live rack power?\u003c\/p\u003e\n\u003cp\u003eA: Hot-insertion and removal of safety modules require adherence to site safety authorization protocols and proper controller override procedures to prevent accidental trip commands.\u003c\/p\u003e\n\u003cp\u003eQ: How does the output circuit react to an external load short-circuit?\u003c\/p\u003e\n\u003cp\u003eA: The output channel incorporates overcurrent protection that trips the driver stage into a safe, de-energized state while reporting a fault diagnostic flag to the controller.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the module straight into the designated Safety Manager I\/O chassis slot, applying steady pressure until the mechanical locking levers engage.\u003c\/li\u003e\n\u003cli\u003eTerminate field actuator wiring securely to the corresponding terminal block, maintaining proper polarity for 24 VDC common-source circuits.\u003c\/li\u003e\n\u003cli\u003eEnsure all shield drain wires from output control cables are terminated to the designated cabinet earth ground bar.\u003c\/li\u003e\n\u003cli\u003eVerify control power supply voltage stability and fuse ratings prior to releasing the safety loop into active service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50622276731160,"sku":"FS-TSDO-0824","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/FC-TSDI-16UNI_Cocoai_fe703af5-6cea-4de3-890b-9dd92743c6f5.jpg?v=1792377036","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-fs-tsdo-0824-safe-digital-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}