{"product_id":"honeywell-fs-pdc-ioip1a-analog-digital-i-o-module","title":"Honeywell FS-PDC-IOIP1A Analog Digital I\/O Module","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-PDC-10IP1a\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFS-PDC-10IP1a\u003c\/strong\u003e Input\/Output Module, operates as a dedicated hardware component for mixed-signal conditioning and real-time field data processing within industrial control systems. It interfaces both digital and analog field signals directly to controller networks, converting field-level voltage and current inputs for processing logic.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-PDC-10IP1a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard industrial I\/O module weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail mount format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 24 VDC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported I\/O\u003c\/td\u003e\n\u003ctd\u003eMixed Digital and Analog signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe FS-PDC-10IP1a incorporates flexible signal conditioning circuits to handle analog and digital inputs without signal distortion. Internal galvanic and channel-to-channel isolation barriers decouple field-side wiring loops from internal processing logic, blocking high-voltage transients and ground loop currents. This isolated architecture ensures stable signal acquisition across 4-20 mA HART instrumentation loops and digital field lines in high-noise electrical environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What operating power is required for the FS-PDC-10IP1a I\/O module?\u003c\/p\u003e\n\u003cp\u003eA: The module operates on a standard 24 VDC nominal power supply for internal circuitry and field loop execution.\u003c\/p\u003e\n\u003cp\u003eQ: How are field wiring ground loops mitigated on the FS-PDC-10IP1a?\u003c\/p\u003e\n\u003cp\u003eA: Channel-to-channel and bus-side isolation circuits decouple individual field wiring runs, preventing ground potential differences from affecting signal accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSnap the FS-PDC-10IP1a module securely onto a standard 35 mm DIN rail inside the enclosure, ensuring the carrier ground clip makes firm contact with the rail.\u003c\/li\u003e\n\u003cli\u003eTerminate analog and digital field wiring to the designated screw terminals, verifying correct polarity and signal type configurations.\u003c\/li\u003e\n\u003cli\u003eConnect the DIN rail to the main cabinet protective earth bar using a short, low-impedance copper strap to protect internal components from ESD.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003etion connections.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAMR04 51305907-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLow-Level Analog Input Multiplexer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels with solid-state relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eCompression terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Technology\u003c\/td\u003e\n\u003ctd\u003eSolid-state relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Termination Assembly Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FTA Slot Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive \/ Backplane Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eEngineered for precision low-level analog instrumentation, the Honeywell MC-TAMR04 multiplexer features solid-state switching matrices designed to interface with sub-volt transducers and 4-20 mA HART loop protocol field devices. High channel-to-channel isolation safeguards sensitive conversion hardware against transient voltage spikes and ground potential differences. The solid-state relay architecture eliminates mechanical contact wear, providing low-noise signal path switching between field sensors and central control processors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What switching mechanism is utilized across the 16 channels of the MC-TAMR04?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates solid-state relays across all 16 input channels to handle low-level signal routing without mechanical wear.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MC-TAMR04 multiplexer support redundant configuration setups?\u003c\/p\u003e\n\u003cp\u003eA: No, the MC-TAMR04 hardware design does not support redundancy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Termination:\u003c\/strong\u003e Strip low-level analog signal conductors to 7 mm and land them into the integrated compression terminal blocks. Torque terminal screws to standard specification to avoid thermal high-resistance connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect individual low-level sensor cable shields directly to the cabinet signal ground bar to maintain high signal-to-noise ratios during relay switching operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Trunking Separation:\u003c\/strong\u003e Route low-level analog input wiring inside dedicated wire ducts separate from high-voltage AC lines to prevent capacitive coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Install the assembly securely onto the designated cabinet carrier file, ensuring correct connector engagement before energizing system power.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52608897286424,"sku":"FS-PDC-IOIP1A","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/FS-PDC-IOIP1A.png?v=1788427085","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-fs-pdc-ioip1a-analog-digital-i-o-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}