{"product_id":"honeywell-fc-tsgas-1624-field-termination-assembly","title":"Honeywell FC-TSGAS-1624 Field Termination Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TSGAS-1624\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-TSGAS-1624\u003c\/strong\u003e Field Termination Assembly, operates as a dedicated hardware component for 16-channel analog signal conditioning and gas\/flame detector interfacing within Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TSGAS-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Chassis Form Factor (Shipping Weight approx. 2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e225 mm x 70 mm x 60 mm (8.86 in x 2.76 in x 2.36 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C (derated from 0.5 A at 25 deg C to 0.35 A at 70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eExternal 24 VDC, 3 mA (without field loads); max input current 0-25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e16 channels, configurable for 0-20 mA or 4-20 mA input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e500 Ohm (+\/-5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0-4 VDC to SAI-1620m module (Accuracy: 0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuses\u003c\/td\u003e\n\u003ctd\u003eSchurter 00012501, 500 mAT, 5 x 20 mm (250 VAC \/ 300 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA Loop Processing and Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module processes standard 0-20 mA or 4-20 mA field transmitter inputs into linear 0-4 VDC output levels required by high-density analog input cards such as the SAI-1620m. Integrated power distribution per channel with 500 mA Schurter fuse protection ensures localized fault containment, preventing loop disturbances from affecting adjacent measurement channels or central processing backplane buses.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the input resistance and conversion accuracy of the FC-TSGAS-1624 module?\u003c\/p\u003e\n\u003cp\u003eA: The module provides an input resistance of 500 Ohm (+\/-5%) and converts 0-20 mA or 4-20 mA field signals into a linear 0-4 VDC output with an accuracy of 0.1%.\u003c\/p\u003e\n\u003cp\u003eQ: What are the wire gauge and tightening torque requirements for the power screw terminals?\u003c\/p\u003e\n\u003cp\u003eA: Power screw terminals (A, B) accommodate a maximum wire size of 16 mm2 (AWG 6) with a 7 mm strip length and a tightening torque of 1.2 Nm (0.88 ft-lb). Standard signal terminals accept up to 2.5 mm2 (AWG 14) wire with a tightening torque of 0.2 Nm (0.17 ft-lb).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the assembly onto TS32 or TS35 x 7.5 DIN rails using a minimum usable rail length of 220 mm (8.90 in).\u003c\/li\u003e\n\u003cli\u003eTerminate field wiring using stripped lengths of 7 mm, tightening signal screws to 0.2 Nm (0.17 ft-lb) and power supply terminals to 1.2 Nm (0.88 ft-lb).\u003c\/li\u003e\n\u003cli\u003eVerify external 24 VDC supply voltage levels and ensure installed Schurter 500 mAT fuses match operational derating curves between 25 deg C and 70 deg C ambient temperatures.\u003c\/li\u003e\n\u003cli\u003eInspect all channel connections to verify proper signal mapping to the downstream SAI-1620m module before system power-up.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49519281242392,"sku":"FC-TSGAS-1624","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/FC-TSAI-1620M_278a10ef-474b-4549-aa0b-fe05adb0ee18.jpg?v=1735292471","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-fc-tsgas-1624-field-termination-assembly","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}