{"product_id":"honeywell-cc-taon11-51306521-175-analog-output-module","title":"Honeywell CC-TAON11 51306521-175 Analog Output Module","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAON11 51306521-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TAON11\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for direct digital-to-analog signal conversion and final control element positioning within Honeywell Series C controllers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAON11 51306521-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.8 cm x 12.7 cm x 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA or 0-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Update Rate\u003c\/td\u003e\n\u003ctd\u003e10 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation and Loop Protocol Performance\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-precision loop execution, the module integrates internal channel-to-channel isolation barriers to block common-mode interference and cross-talk across control outputs. Real-time signal conditioning maintains +\/-0.1% accuracy over temperature drifts, supporting reliable 4-20 mA HART feedback loops for control valves, variable frequency drives, and positioners. Thermal dissipation design allows continuous 1.5 W per channel loading across full extended operating profiles without degradation of digital-to-analog converter resolution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is field cabling terminated to the CC-TAON11 module?\u003c\/p\u003e\n\u003cp\u003eA: Field cables connect directly to the underlying Input Output Termination Assembly (IOTA) screw terminals, isolating physical field wiring from the active electronic processing module.\u003c\/p\u003e\n\u003cp\u003eQ: What output modes can be configured on the channel interfaces?\u003c\/p\u003e\n\u003cp\u003eA: Channels are software-configurable within the Experion PKS environment to supply either a 4-20 mA current loop or a 0-10 V DC control signal.\u003c\/p\u003e\n\u003cp\u003eQ: Does module removal disrupt the continuity of field termination circuits?\u003c\/p\u003e\n\u003cp\u003eA: No, removing the active electronic card from the IOTA carrier preserves field wiring connections and ground shield integrity across adjacent channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the IOTA assembly onto the cabinet carrier rack using standard hardware. Maintain a minimum separation distance of 100 mm between low-voltage signal cabling and high-voltage AC power lines to minimize induced noise. Connect all field cable shield wires directly to the panel single-point earth busbar. Torque terminal connector screws to standard specifications to prevent high-resistance electrical connections.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52783251095832,"sku":"CC-TAON11 51306521-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/CC-TDOD51_Cocoai_3f377a03-275a-4e57-929d-c6cfc1e3082f.png?v=1790584343","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-cc-taon11-51306521-175-analog-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}