{"product_id":"honeywell-cc-taix11-51308365-175-c300-i-o-series","title":"Honeywell CC-TAIX11 51308365-175 C300 I\/O Series","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAIX11 51308365-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TAIX11\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for high-accuracy analog signal acquisition and fault-tolerant redundant loop monitoring within Honeywell TotalPlant Solution (TPS) and Experion C300 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAIX11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg (0.84 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e294 mm x 120 mm x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51308365-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage (0-5 V), Current (4-20 mA), Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e+\/-0.02%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-logic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eRedundant Analog Input Module (RAIM) \/ Hot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TPS \/ Experion C300 \/ Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; DCS Field Signal Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TAIX11 incorporates high-performance galvanic channel-to-channel isolation barriers to eliminate common-mode noise and prevent cross-talk across multi-channel transmitter wiring. When integrated into distributed control system (DCS) architectures, the module monitors process variables including temperature, differential pressure, and volumetric flow. The internal processing circuits fully support 4-20 mA HART loop protocol telemetry, passing digital device diagnostics directly through the Series C I\/O bus to central controllers. Integrated cold junction compensation (CJC) algorithms dynamically stabilize thermocouple input readings during ambient panel temperature swings, preventing measurement drift across critical safety and process loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-TAIX11 support online module replacement (hot-swapping) while the control system is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The CC-TAIX11 module is fully hot-swappable, allowing live insertion and removal from the Series C Input Output Termination Assembly (IOTA) without interrupting DCS operation or disrupting redundant partner modules.\u003c\/p\u003e\n\u003cp\u003eQ: What input signal ranges can be configured on the CC-TAIX11 analog input channels?\u003c\/p\u003e\n\u003cp\u003eA: Each input channel can be individually configured to accept 0-5 VDC voltage signals, 4-20 mA current loops, or direct millivolt thermocouple sensors.\u003c\/p\u003e\n\u003cp\u003eQ: How does the Redundant Analog Input Module (RAIM) architecture handle channel faults?\u003c\/p\u003e\n\u003cp\u003eA: In a redundant IOTA configuration, dual CC-TAIX11 modules evaluate signal integrity simultaneously. If an internal diagnostic routine detects a channel hardware failure, the secondary module seamlessly takes over signal processing without loop disturbance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the CC-TAIX11 directly onto a compatible Series C IOTA board mounted within a NEMA-rated enclosure. Ensure the module locking latches are completely disengaged before pressing the module firmly into the board connectors, then secure the mechanical latches to lock the assembly in place.\u003c\/p\u003e\n\u003cp\u003eField transmitter cables must be connected using shielded twisted-pair conductors terminated at the IOTA screw terminals. Route low-voltage analog input leads in dedicated panel wiring ducts separated from high-voltage AC lines and variable frequency drive output cables to minimize electromagnetic coupling. Connect all cable drain wires to the designated panel earth grounding bar, maintaining ground contact resistance at less than 1 ohm.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52836506042648,"sku":"CC-TAIX11 51308365-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/CC-TAOX11_Cocoai_6da13f17-af3e-4441-8c54-4e5dbb5a3d28.png?v=1791511708","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-cc-taix11-51308365-175-c300-i-o-series","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}