{"product_id":"honeywell-cc-pdob01-51405043-175-digital-output-module","title":"Honeywell CC-PDOB01 51405043-175 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PDOB01 51405043-175\u003c\/strong\u003e , also cataloged as the \u003cstrong\u003eCC-PDOB01\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for 24 VDC signal switching and field actuation within Honeywell C300 and Experion PKS control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PDOB01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51405043-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.231 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e63.5 x 124.46 x 307.34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (30 VDC max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC RMS or +\/-1500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=10 ms turn-on\/turn-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=0.5 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Solid-State Load Switching\u003c\/h3\u003e\n\u003cp\u003eDesigned with a high-density 32-channel output matrix, the \u003cstrong\u003eHoneywell CC-PDOB01 51405043-175\u003c\/strong\u003e incorporates high-performance galvanic isolation barriers rated up to 1500 VAC RMS. Internal solid-state switching circuitry provides high noise immunity and prevents backplane transient voltage propagation during high-inductive load switching events. Integrated output conditioning suppresses off-state leakage current to \u0026lt;=0.5 uA, eliminating false actuation on low-power field relays and solenoid valves.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power bus grounding protocols apply to the 24 VDC field power supply feeding this module? A: Field power supplies must be tied to a dedicated isolated DC common bus, ensuring galvanic isolation from the system backplane ground to maintain the 1500 VAC RMS isolation threshold.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle inductive load flyback voltages on field solenoids? A: While internal solid-state switches provide fast switching times, external inductive field devices require external flyback suppression diodes installed directly across the load terminals to prevent inductive voltage spikes from damaging output channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that external 24 VDC field supply power is de-energized prior to inserting the module into the I\/O terminal assembly.\u003c\/li\u003e\n\u003cli\u003eEnsure all field wiring shields are properly grounded at the designated enclosure bus and not daisy-chained across channel terminals.\u003c\/li\u003e\n\u003cli\u003eVerify total current load per output group does not exceed maximum backplane power limits during simultaneous channel activation.\u003c\/li\u003e\n\u003cli\u003eAllow proper clearance above and below the module rack to facilitate vertical airflow and convective heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52611928031512,"sku":"CC-PDOB01 51405043-175","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/HoneywellCC-PAIH01_Cocoai.png?v=1788513826","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-cc-pdob01-51405043-175-digital-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}