{"product_id":"honeywell-8c-tdil61-51306967-175-analog-input","title":"Honeywell 8C-TDIL61 51306967-175 Analog Input","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eConfigured for 4-20 mA analog signal acquisition and HART protocol pass-through in Experion PKS Series 8 C300 controllers, the \u003cstrong\u003eHoneywell 8C-TDIL61 51306967-175\u003c\/strong\u003e (\u003cstrong\u003e8C-TDIL61\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TDIL61 hardware platform supports high-level 4-20 mA inputs across 16 channels, configurable for single-ended or differential terminal topologies with optional secondary HART variable pass-through.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eChannel Density\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eHART Protocol Support\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e8C-TDIL61\u003c\/td\u003e\n\u003ctd\u003e51306967-175\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003ctd\u003eIntegrated Pass-Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TDIL61 51306967-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.8 cm x 8.7 cm x 7.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCarrier backplane driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels (Single-ended \/ Differential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003e4-20 mA HART loop protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and bus galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Loop Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TDIL61 integrates channel-to-channel galvanic isolation barriers to decouple sensitive 4-20 mA loop processing from field ground potential shifts and high-voltage spikes. Onboard cold junction compensation (CJC) tracing and digital noise filtering preserve measurement accuracy across all 16 channels, enabling primary, secondary, and tertiary HART field device variables to be extracted and routed directly into control logic without signal degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8C-TDIL61 support live module insertion and removal (hot-swapping)?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports Removal and Insertion Under Power (RIUP) when installed on a live Series 8 I\/O carrier, maintaining uninterrupted operations across adjacent slots.\u003c\/p\u003e\n\u003cp\u003eQ: Can HART secondary and tertiary process variables be accessed directly as process control inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The onboard HART modem extracts secondary, tertiary, and quaternary variables from the 4-20 mA carrier loop and presents them to the Experion control platform as standard control variables.\u003c\/p\u003e\n\u003cp\u003eQ: What input terminal configurations are supported on the 16-channel interface?\u003c\/p\u003e\n\u003cp\u003eA: The module supports both single-ended and differential wiring connections depending on the selected field termination assembly and loop power configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Slot Alignment\u003c\/strong\u003e: Align the 8C-TDIL61 card guides with the target slot on the Series 8 carrier and push firmly until the dual retention levers latch into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Terminate all field transmitter cable shields at the cabinet grounding bar using standard grounding clamps. Ensure a single-point ground connection to eliminate ground loop currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Wire Separation\u003c\/strong\u003e: Route 4-20 mA low-level analog signal leads in dedicated wiring trays, maintaining at least 50 mm clearance from high-voltage power leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Integrity\u003c\/strong\u003e: Verify that all conduit entries maintain a minimum engagement of 5 full threads to preserve junction integrity and shield enclosure grounding.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52751410561304,"sku":"8C-TDIL61 51306967-175","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/8C-TDIL6151306967-1752_Cocoai.jpg?v=1790149925","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-8c-tdil61-51306967-175-analog-input","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}