{"product_id":"honeywell-8c-taixa1-51307127-175-analog-input-module","title":"Honeywell 8C-TAIXA1 51307127-175 Analog Input Module","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eConfigured for multi-signal analog data conversion in Experion PKS Series 8 platforms, the \u003cstrong\u003eHoneywell 8C-TAIXA1 51307127-175\u003c\/strong\u003e (\u003cstrong\u003e8C-TAIXA1\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAIXA1 51307127-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 cm x 12.0 cm x 15.24 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-20 mA, 0-10 V, resistive inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Loop Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TAIXA1 module integrates optical channel isolation to decouple field-side measurement loops from internal Experion backplane logic, preventing common-mode voltage spikes and electrical noise propagation. Compatible with 4-20 mA HART loop protocol parameters, the module architecture includes dedicated signal conditioning for high-impedance voltage signals and resistive sensors, utilizing cold junction compensation (CJC) trace references to stabilize differential sensor readings in harsh electrical environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 8C-TAIXA1 module be inserted or removed under power during live controller operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports Removal and Insertion Under Power (RIUP) on compatible Series 8 carrier racks without interrupting adjacent I\/O processing loops.\u003c\/p\u003e\n\u003cp\u003eQ: What input impedance characteristics apply to current and voltage signal channels?\u003c\/p\u003e\n\u003cp\u003eA: Current channels present an input impedance greater than 250 Ohm, while voltage measurement circuits provide an input impedance exceeding 1 MOhm to minimize signal loading errors.\u003c\/p\u003e\n\u003cp\u003eQ: How is physical chassis grounding established for the 8 input channels?\u003c\/p\u003e\n\u003cp\u003eA: Grounding is established through the carrier baseplate ground bar connections, diverting high-frequency field transients away from internal ADC conversion logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Alignment\u003c\/strong\u003e: Align the module edge guide with the designated slot on the Series 8 carrier assembly and press firmly until the locking levers seat completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Terminate all field transmitter cable drain wires at the cabinet instrument earth bus bar using standard grounding clamps. Maintain a single-point earth ground to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation\u003c\/strong\u003e: Route low-level analog signal leads in independent wire ducts, maintaining a minimum 50 mm clearance from high-voltage AC conductors and motor power cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connections\u003c\/strong\u003e: Secure all field signal wiring to the removable terminal block (RTB) screws, ensuring proper torque and maintaining a minimum engagement of 5 full threads on conduit fittings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52751438119192,"sku":"8C-TAIXA1 51307127-175","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/HoneywellCC-TAIX1151308365-175_Cocoai_29810d4e-5e28-4a6d-bcf0-aef44fd7312b.png?v=1790150031","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-8c-taixa1-51307127-175-analog-input-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}