{"product_id":"honeywell-8c-taix51-series-8-high-density-analog-input-module","title":"Honeywell 8C-TAIX51 Series 8 High-Density Analog Input Module","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cp\u003eConfigured for high-density analog signal processing in Honeywell Experion PKS platforms, the \u003cstrong\u003eHoneywell 8C-TAIX51\u003c\/strong\u003e (\u003cstrong\u003e51306979-175\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51306979-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.1 cm x 15.7 cm x 14.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Series 8 IOTA backplane power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, +-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e250 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell C300 controller, Experion PKS systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8C-TAIX51 incorporates individual channel-to-channel galvanically isolated input stages to eliminate ground loop current errors and suppress high-frequency common-mode noise across all 16 input channels. Designed to process both 4-20 mA current loops and +-10 V DC differential signals with 12-bit analog-to-digital resolution, the module passes HART digital communication signals transparently to Experion PKS asset management applications. The 250 ms scan cycle delivers deterministic thermal and pressure variable updates directly to C300 execution environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8C-TAIX51 module support hot-swapping under powered conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module can be removed or plugged directly into an active IOTA base on Experion PKS Series 8 racks without interrupting controller backplane execution or impacting adjacent I\/O channel states.\u003c\/p\u003e\n\u003cp\u003eQ: What input signal ranges can be configured on the 16 channels of the 8C-TAIX51?\u003c\/p\u003e\n\u003cp\u003eA: Each individual input channel accommodates standard 4-20 mA industrial current signals as well as +-10 V DC analog voltage inputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the guide channels on the target IOTA mounting position are clear of debris prior to inserting the 8C-TAIX51 module.\u003c\/li\u003e\n\u003cli\u003eAlign the edge connector board on the module base with the IOTA receptacle, pressing firmly until both retaining tabs latch into position.\u003c\/li\u003e\n\u003cli\u003eWire field transmitter loops using twisted shielded pairs, connecting cable drain wires to the designated shield grounding terminal on the IOTA assembly at one end only.\u003c\/li\u003e\n\u003cli\u003eRoute analog field signal cabling in dedicated low-voltage cable trays separate from 120\/230 VAC power distribution lines.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52790054027544,"sku":"8C-TAIX51 51306979-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/8U-TPOX0151307022-175_0f296e54-709c-4e2d-b1fe-1f49948a84b9.png?v=1790733727","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-8c-taix51-series-8-high-density-analog-input-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}