{"product_id":"honeywell-8c-pdoda1-series-8-digital-output-module","title":"Honeywell 8C-PDODA1 Series 8 Digital Output Module","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-PDODA1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51454472-175\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete signal switching and load driving within Experion PKS Series 8 I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-PDODA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454472-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e61 mm x 153 mm x 144 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e95 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 discrete channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Load Capacity\u003c\/td\u003e\n\u003ctd\u003e0.5 A max per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSeries 8 chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Solid-State Switching\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8C-PDODA1 provides channel-to-channel isolation to prevent electrical transients, switching noise, and inductive kickback from propagating into the Series 8 backplane bus. Each of the 16 solid-state digital output channels drives 24 VDC control power to solenoids, relays, and field actuators at up to 0.5 A per channel. Integrated diagnostic monitoring continuously evaluates output channel status and fault conditions, ensuring deterministic discrete switching execution across fault-tolerant, redundant Experion PKS architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 8C-PDODA1 module be hot-swapped while the Series 8 system is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is hot-swappable and can be inserted into or removed from an active IOTA base without interrupting controller logic or disturbing adjacent active I\/O channels.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum continuous current rating for each output channel on the 8C-PDODA1?\u003c\/p\u003e\n\u003cp\u003eA: Each channel supports a maximum continuous load current of 0.5 A at 24 VDC. Exceeding individual channel limits triggers onboard protection mechanisms to prevent thermal overload.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the designated IOTA slot on the Series 8 carrier chassis to ensure connector pins are clean and free of contaminants.\u003c\/li\u003e\n\u003cli\u003eAlign the guide edges of the 8C-PDODA1 chassis with the IOTA slot guides and push the module firmly until the backplane connector fully locks into position.\u003c\/li\u003e\n\u003cli\u003eTerminate 24 VDC actuator, solenoid, and relay field wiring onto the corresponding IOTA terminal strip points.\u003c\/li\u003e\n\u003cli\u003eSeparate discrete output supply cabling from low-level analog input lines and communication buses inside cabinet wire ducts to prevent transient coupling.\u003c\/li\u003e\n\u003cli\u003eApply field control power and verify that channel status LEDs indicate proper diagnostic initialization before placing output channels in automatic control mode.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52790054125848,"sku":"8C-PDODA1 51454472-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/HoneywellCC-PAIH01_Cocoai_140cc73f-d537-4162-8dbd-74b495f42e25.png?v=1790733782","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-8c-pdoda1-series-8-digital-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}