{"product_id":"honeywell-80363969-150-output-module","title":"Honeywell 80363969-150 Output Module","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 80363969-150\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e80363969\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for converting digital control signals into multi-channel current loops within Honeywell DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModule Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSignal Format\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e80363969\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase\u003c\/td\u003e\n\u003ctd\u003eStandard 16-Channel Analog Output Circuit Board\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e80363969-150\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-150\u003c\/td\u003e\n\u003ctd\u003eConformal Coated 16-Channel High-Density Output Module\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e80363969-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DCS I\/O Rack Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA Current Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eVDC Logic I\/O Module \/ Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Loop Stability\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates channel-to-channel isolation parameters engineered to eliminate signal cross-talk and prevent ground loop interference across all 16 independent 4-20 mA loops. By decoupling field side electrical transients from the backplane bus, the module preserves signal fidelity for final control elements such as control valve positioners and variable frequency drives. Internal current regulation circuits maintain stable signal drive capabilities across varying field loop load impedances under full operational load.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the Honeywell 80363969-150 module be inserted or removed under live backplane power?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is permissible provided the field termination assembly is disconnected or isolated first to prevent transient electrical spikes across the backplane edge connector pins during insertion.\u003c\/p\u003e\n\u003cp\u003eQ: What power source drives the 4-20 mA field loops on this module?\u003c\/p\u003e\n\u003cp\u003eA: The module operates from an internal 24 VDC backplane supply bus or system I\/O power rail to source current for all 16 analog output loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm system ground bonding meets factory specifications with low impedance connection to earth prior to card insertion.\u003c\/li\u003e\n\u003cli\u003eAlign module board edges with backplane guide rails and slide card horizontally until edge connectors seat completely into the backplane.\u003c\/li\u003e\n\u003cli\u003eEnsure all 4-20 mA output signal cables use twisted shielded pair construction with single-point shielding connected at the cabinet ground bar.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring termination block screws are torqued to manufacturer terminal specifications to maintain reliable connection integrity.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52688922575128,"sku":"80363969-150","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/80363972-150_Cocoai_57c8cd99-e39b-4177-9af3-1bf910ba4b6b.jpg?v=1789544402","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-80363969-150-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}