{"product_id":"honeywell-51454472-175-digital-output","title":"Honeywell 51454472-175 Digital Output","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cp\u003eConfigured for discrete signal switching and load driving in Experion PKS Series 8 I\/O architecture, the \u003cstrong\u003eHoneywell 51454472-175\u003c\/strong\u003e (\u003cstrong\u003e8C-PDODA1\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-PDODA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454472-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e61 mm x 153 mm x 144 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e95 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 discrete channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Load Capacity\u003c\/td\u003e\n\u003ctd\u003e0.5 A max per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Solid-State Switching\u003c\/h3\u003e\n\u003cp\u003eDesigned within Honeywell DCS standards, the 8C-PDODA1 digital output card provides channel-to-channel isolation to prevent electrical transients and inductive kickback from entering the Series 8 internal backplane bus. Each of the 16 solid-state channels regulates 24 VDC control power to solenoids, relays, and field actuators while delivering precise current limiting per channel. Differential switching logic combined with real-time status diagnostics ensures deterministic output control across dual-redundant I\/O configurations under heavy industrial noise conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the Honeywell 51454472-175 digital output module be hot-swapped while the system is operating?\u003c\/p\u003e\n\u003cp\u003eA: Yes, this module supports hot-swap installation on active Series 8 IOTA bases. Removing or inserting the module under power does not disrupt logic execution on adjacent active channels or trigger false state transitions on the backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum allowable load current per output channel on the 8C-PDODA1?\u003c\/p\u003e\n\u003cp\u003eA: Each individual output channel supports up to 0.5 A continuous load at 24 VDC. Exceeding this limit triggers internal electronic overcurrent protection circuits to safeguard channel electronics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the designated slot on the Series 8 IOTA mounting base is clean and free of conductive debris before physical installation.\u003c\/li\u003e\n\u003cli\u003eAlign the guide ribs of the 51454472-175 module chassis with the mating tracks on the IOTA carrier board.\u003c\/li\u003e\n\u003cli\u003eSlide the module into position and press firmly until the multi-pin backplane connector fully seats into the receptacle socket. Secure all retaining screws to standard torque limits.\u003c\/li\u003e\n\u003cli\u003eWire field actuators to the corresponding IOTA terminal block terminals. Ensure field supply cabling is routed separately from low-level analog or communication cables.\u003c\/li\u003e\n\u003cli\u003eEnergize system loop power, observe front-panel status LED indications for proper diagnostic startup, and execute channel loop checks prior to engaging automatic control outputs.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52790048719128,"sku":"51454472-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/CC-PUIO01_Cocoai_4ae84708-2303-44dd-af0e-e53716c70ed8.png?v=1790733118","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-51454472-175-digital-output","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}