{"product_id":"honeywell-51454416-200-hpm-i-o-link-module","title":"Honeywell|51454416-200|HPM I\/O Link Module","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\" data-spm-anchor-id=\"5176.28103460.0.i36.460b7551ttmJPL\"\u003eHoneywell 51454416-200 HPM I\/O Link Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eHoneywell 51454416-200 is a High Performance Process Manager (HPM) I\/O Link Module specifically engineered for the TDC 3000 Distributed Control System to provide redundant high-speed communication links between the HPM processor and Universal I\/O carriers.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eSupports fully redundant I\/O link configurations for maximum availability. Connects HPM processors to multiple I\/O carriers simultaneously. Ensures deterministic and synchronized data transfer. Compatible with TDC 3000 LCN and UCN network architectures.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSystem Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Honeywell TDC 3000 LCN\/UCN Network Architecture\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eModule Type\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Redundant HPM I\/O Link Interface Board\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 51454416-200\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eData Transfer Rate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: High-speed synchronous communication optimized for sub-second process control cycles\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eI\/O Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Supports connection to up to 40 Universal I\/O (UIO) carriers per redundant link pair\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eRedundancy Support\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Hardware-based dual-link redundancy with automatic failover capability\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 0°C to 60°C (32°F to 140°F) industrial grade range\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: -40°C to 85°C (-40°F to 185°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePower Requirement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\" data-spm-anchor-id=\"5176.28103460.0.i37.460b7551ttmJPL\"\u003e: Powered via HPM backplane, nominal 5 VDC ±5% logic levels\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eCurrent Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Approximately 1.2 A at 5 VDC typical operation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eCommunication Protocol\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Proprietary Honeywell HPM I\/O Link Protocol\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSlot Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Occupies dedicated I\/O Link slots A and B within HPM cabinet for redundancy\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eReliability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Mean Time Between Failures (MTBF) exceeding 150,000 hours in redundant configuration\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePhysical Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Standard Eurocard form factor 100 mm x 160 mm fitting HPM chassis\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Approximately 0.55 kg including heavy-duty connectors\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51837515727128,"sku":"51454416-200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/g_1291d2ba-e97d-4a28-b14f-7f78d79e2492.jpg?v=1734069363","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-51454416-200-hpm-i-o-link-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}