{"product_id":"honeywell-51304453-150-analog-input-module","title":"Honeywell 51304453-150 Analog Input Module","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51304453-150\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51304453-150\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for high-level analog signal conversion and smart transmitter interface (STI) processing within Honeywell TDC 3000 and Experion Process Knowledge System (PKS) process control racks. It processes high-level process variables and digitizes incoming current and voltage loops for direct controller execution via an integrated compression terminal assembly.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg (2.2 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Process Manager I\/O Slot Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (+32 to +140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane logic bus powered via card file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input \/ Smart Transmitter Interface (STI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eIntegrated compression terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg (6.6 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Compliance\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eEngineered to maintain signal purity within dense control cabinets, the module incorporates robust channel-to-channel isolation and common-mode transient suppression to shield analog-to-digital conversion stages from field ground potential differences. The hardware natively interfaces with smart transmitters, supporting digital communications alongside 4-20 mA HART loop protocol signals. Precision cold junction compensation (CJC) processing and active RC filtering attenuate line noise at industrial frequencies, preserving measurement accuracy for critical loop variables.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are field wiring connections terminated on the 51304453-150 module?\u003c\/p\u003e\n\u003cp\u003eA: Field conductors are connected directly to the module via an integrated compression terminal block, eliminating the need for external screw-terminal sub-assemblies.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module protect internal system logic against field-side electrical noise?\u003c\/p\u003e\n\u003cp\u003eA: High-density galvanic and optical channel-to-channel isolation barriers prevent common-mode voltage spikes and ground loop currents from propagating to the central backplane bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eTurn off rack power supply units or follow Honeywell live-insertion guidelines before installing or removing the 51304453-150 module.\u003c\/li\u003e\n\u003cli\u003eAlign the board edges with the card guide rails of the target slot in the I\/O card file rack.\u003c\/li\u003e\n\u003cli\u003eSlide the assembly in firmly until the rear edge connector fully engages the backplane socket, then tighten mechanical locking screws.\u003c\/li\u003e\n\u003cli\u003eStrip field conductor ends and secure them into the compression terminal block, ensuring proper polarity for 2-wire and self-powered loops.\u003c\/li\u003e\n\u003cli\u003eConnect cable shield drain wires to a single cabinet earth ground busbar to eliminate low-frequency signal distortion.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52693386264856,"sku":"51304453-150","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/MU-TAIH02_1_9bea656e-078c-4de1-b653-243c10f257ac.png?v=1789614214","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-51304453-150-analog-input-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}