{"product_id":"honeywell-51204172-175-analog-output-module","title":"Honeywell 51204172-175 Analog Output Module","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51204172-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51204172-175\u003c\/strong\u003e (MC-TAOY22) Analog Output Module, operates as a dedicated hardware component for precise current loop signal drive within Honeywell High-Performance Process Manager (HPM) and Experion PKS architectures. It converts digital controller commands into isolated analog output control signals, driving final control elements such as control valves, positioners, and variable speed drives across industrial process networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51204172-175 (MC-TAOY22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (0.77 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e300 mm x 120 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC backplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Field Termination \/ Card Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eCompression terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubsystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHigh-Performance Process Manager (HPM) \/ Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol Integration and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eEngineered for critical process control loops, the 51204172-175 incorporates robust galvanic channel-to-channel isolation between individual output circuits and internal system logic. This prevents high-voltage noise transients, ground loops, and signal cross-talk from affecting central processing units or adjacent analog channels. The module seamlessly handles 4-20 mA HART loop protocol communications, allowing HART-compliant field positioners and smart actuators to transmit digital diagnostic telemetry overlaid on the primary analog current signal without degrading control signal integrity or altering cold junction compensation baseline measurements on adjacent input cards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 51204172-175 MC-TAOY22 module be replaced online while the rest of the node remains energized?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping of the circuit assembly is supported provided the field signal compression terminal connectors are disconnected or field loops are safely isolated prior to card removal.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field wiring termination does the 51204172-175 accept directly on the assembly?\u003c\/p\u003e\n\u003cp\u003eA: The board features integrated screw compression terminals, designed to secure solid or stranded field conductors directly without requiring auxiliary termination blocks.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the host I\/O card chassis slot corresponds to the correct physical address mapped in the system control configuration.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edges with the internal chassis mounting guides and slide the assembly into the slot until the connectors engage the backplane socket.\u003c\/li\u003e\n\u003cli\u003eTighten the faceplate retaining screws to ensure stable structural grounding against the cabinet frame.\u003c\/li\u003e\n\u003cli\u003eWire field output loops to the compression terminals, adhering to polarity markings and stripping wire ends to 7 mm.\u003c\/li\u003e\n\u003cli\u003eGround all cable shield drain wires at the designated cabinet grounding rail to ensure optimum immunity against electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52702985617688,"sku":"51204172-175","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/MC-TDOY22_2_00852ea0-4585-4f4e-98b5-0123b68b36dc.png?v=1789719078","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-51204172-175-analog-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}