{"product_id":"honeywell-51191699-100-switch-proximity-detector-interface-unit","title":"Honeywell|51191699-100|Switch\/Proximity Detector Interface Unit","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHONEYWELL 51191699-100 (MTL4016) Switch\/Proximity Detector Interface Unit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eHONEYWELL 51191699-100 is a dual-channel galvanic isolation module designed for safe interfacing of switches and proximity detectors from hazardous areas to safe-area control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDual-channel operation with independent phase reversal switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eBuilt-in line fault detection (IFD) for broken or shorted lines\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eRedundancy support for critical applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eLED indicators for power and channel status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eNumber of Channels: Two\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eHazardous Area Rating: Zone 0, IIC, T6 (Div.1, Group A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSensor Voltage: 7.0V – 9.0V dc via 1kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eOutputs Closed: \u0026gt;2.1mA (\u0026lt;2kΩ) in sensor circuit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eOutputs Open: \u0026lt;1.2mA (\u0026gt;10kΩ) in sensor circuit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eHysteresis: 200µA (650Ω) nominal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eLine Fault Detection: Outputs open if input current \u0026lt;100µA (broken line) or \u0026gt;6.5mA (shorted line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eRelay Output: Double-pole, 10W \/ 0.5A \/ 35V dc max, response time 2ms max\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eContact Life Expectancy: 10⁶ operations at maximum load\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePower Requirement: 50mA at 24V dc \/ 45mA at 35V dc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePower Dissipation: 1.2W at 24V \/ 1.6W at 35V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIsolation: 250V ac between safe and hazardous area circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSafety Description (per channel): 10.5V \/ 800Ω \/ 14mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eFM Entity Parameters: Voc = 10.5V dc, Isc = 14mA, Ca = 2.4µF, La = 165mH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eOperating Temperature: -40°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWeight: Approx. 0.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52108917735704,"sku":"51191699-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/Honeywell_MU_TAIH02_View1_202110115158.jpg?v=1729738434","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-51191699-100-switch-proximity-detector-interface-unit","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}