{"product_id":"general-electric-is200tbacih1b-mark-vie-terminal-contact-board","title":"General Electric IS200TBACIH1B Mark VIe Terminal Contact Board","description":"\u003cdiv class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200TBACIH1B\u003c\/strong\u003e is identified in the supplied product description as a terminal contact board for interfacing field wiring with a Mark VIe control system. It provides termination points for discrete input and output signals, with a 50-pin ribbon cable interface to the controller. The supplied listing also specifies 24 VDC operation, per-channel surge suppression, and LED status indication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBACIH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Contact Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Function\u003c\/td\u003e\n\u003ctd\u003eField signal termination and I\/O interfacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eDigital inputs and relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Positions\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Interface\u003c\/td\u003e\n\u003ctd\u003e50-pin ribbon cable header\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Draw\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e0.5-2.5 mm2 (20-14 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Suppression\u003c\/td\u003e\n\u003ctd\u003eBuilt-in per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003ePower and channel status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Points\u003c\/td\u003e\n\u003ctd\u003eIndividual signal path troubleshooting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D)\u003c\/td\u003e\n\u003ctd\u003e229 x 178 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Overall Dimensions\u003c\/td\u003e\n\u003ctd\u003e229 x 178 x 1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Interface and Field Termination\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBACIH1B provides 24 numbered terminal positions for connecting field devices to the control system. Its terminal arrangement creates an organized interface between external wiring and the controller-side connection, helping maintenance personnel identify individual signal paths during installation and troubleshooting.\u003c\/p\u003e\n\u003cp\u003eThe supplied description identifies support for digital input and relay output signals, as well as sinking and sourcing configurations. These configurations determine how field circuits exchange current with the connected I\/O circuitry. Actual channel assignments and electrical limits should be checked against the applicable GE wiring documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eController Connectivity and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe board uses a 50-pin ribbon cable header for its controller interface. This connection carries the associated I\/O signals between the terminal board and the control hardware. The supplied specifications also identify built-in surge suppression for each channel, intended to limit transient disturbances entering through field connections.\u003c\/p\u003e\n\u003cp\u003ePower and channel activity LEDs provide local status indications. Individual test points are also specified for checking signal paths during maintenance. These features support circuit-level troubleshooting without relying solely on controller diagnostics.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMounting and Wiring Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied product information specifies installation on a standard 35 mm DIN rail or by panel mounting. Field conductors are specified for wire sizes from 0.5 mm2 to 2.5 mm2 (20-14 AWG).\u003c\/p\u003e\n\u003cp\u003eBefore installation, verify the controller interface assignment, terminal numbering, field signal type, and wiring polarity. The ribbon cable must be connected to the corresponding controller interface. Terminal tightening torque is not provided in the supplied information and should be confirmed from the applicable installation documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of signals can the IS200TBACIH1B connect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied description identifies digital inputs and relay output signals. It also specifies sinking and sourcing configurations, subject to the actual channel wiring and system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the IS200TBACIH1B connect to the controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It uses a 50-pin ribbon cable header as its controller-side interface. The corresponding controller port and cable compatibility should be verified before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power supply does the IS200TBACIH1B require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied product listing specifies a 24 VDC power supply and a maximum current draw of 200 mA. Confirm these ratings against the applicable GE documentation before energizing the board.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53305517605144,"sku":"IS200TBACIH1B","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/IS200TBACIH1B2_Cocoai.jpg?v=1794797171","url":"https:\/\/www.innoplcsync.com\/products\/general-electric-is200tbacih1b-mark-vie-terminal-contact-board","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}