{"product_id":"ge-is200epctg1a-ex2100-pt-ct-terminal-board","title":"GE IS200EPCTG1A EX2100 PT\/CT Terminal Board","description":"\u003cdiv class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200EPCTG1A\u003c\/strong\u003e is an Exciter PT\/CT Board (EPCT) designed for the GE EX2100 excitation control system. It receives generator potential transformer (PT) voltage and current transformer (CT) current feedback, then conditions, scales, and isolates these signals for the excitation control system. The board supports feedback inputs from two generators and provides three terminal blocks for field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EPCTG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eEPCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Description\u003c\/td\u003e\n\u003ctd\u003eExciter PT\/CT Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Type\u003c\/td\u003e\n\u003ctd\u003eInput\/Output Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eGenerator PT\/CT feedback reception and signal conditioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Feedback Sources\u003c\/td\u003e\n\u003ctd\u003eTwo generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT Input Configuration\u003c\/td\u003e\n\u003ctd\u003eThree-phase generator voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Input Current Levels\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Signal Range\u003c\/td\u003e\n\u003ctd\u003e0-10 V or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT\/CT Input Burden\u003c\/td\u003e\n\u003ctd\u003eLess than 1 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wire Gauge\u003c\/td\u003e\n\u003ctd\u003e#10 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Length\u003c\/td\u003e\n\u003ctd\u003e1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Frequency Noise Suppression\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant System Configuration\u003c\/td\u003e\n\u003ctd\u003eUp to 3 EPCT boards, if required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003ePT and CT Feedback Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IS200EPCTG1A receives voltage and current feedback from generator PTs and CTs. Its PT inputs accommodate three-phase voltage feedback, while its CT inputs accept nominal current levels of 1 A or 5 A from two generators.\u003c\/p\u003e\n\u003cp\u003eThe board conditions these incoming signals by scaling and isolating them before interfacing with the excitation control system. This allows generator electrical measurements to be presented in a suitable form for downstream control and monitoring functions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Signal Conditioning and Noise Suppression\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe EPCT supports analog signal ranges of 0-10 V and 4-20 mA. These ranges are relevant when identifying the signal interface and checking the wiring requirements of the connected measurement circuits.\u003c\/p\u003e\n\u003cp\u003eHigh-frequency noise suppression is provided near the signal entry point. This helps limit high-frequency interference entering through field wiring before the signals are processed by the board.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWiring and Terminal Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe board provides three terminal blocks for PT and CT signal connections. The specified maximum conductor size is #10 AWG, and the maximum cable length is 1000 ft.\u003c\/p\u003e\n\u003cp\u003ePT and CT wiring should be checked against the actual generator measurement circuit configuration. Correct identification of current transformer polarity, phase association, and voltage input connections is necessary when commissioning or replacing the board.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement and Redundant Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor a three-wire open-delta voltage measurement, the supplied product information specifies an output measurement of \u003cstrong\u003e1.533 VRMS for a 115 VRMS input\u003c\/strong\u003e. This value is associated with the stated open-delta measurement condition and should not be treated as a universal voltage conversion ratio for other PT configurations.\u003c\/p\u003e\n\u003cp\u003eAlthough EPCT boards are generally not required in redundant system configurations, the supplied technical information indicates that up to three EPCT boards can be configured when the system design requires them.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What CT current input levels does the IS200EPCTG1A accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The board accepts generator CT input levels of 1 A or 5 A. The received signals are also interfaced to the EMIO board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IS200EPCTG1A provide high-frequency noise suppression?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. High-frequency noise suppression is applied near the signal entry point to help reduce interference entering through the field connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What measurement does the board provide for a three-wire open-delta configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied technical data specifies 1.533 VRMS for a 115 VRMS input under the stated three-wire open-delta measurement condition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many EPCT boards can be used in a redundant system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Up to three EPCT boards can be configured if required. However, EPCT boards are generally not necessary in redundant system configurations.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53305577013528,"sku":"IS200EPCTG1A","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/IS200EPCTG1A2_Cocoai.jpg?v=1794797755","url":"https:\/\/www.innoplcsync.com\/products\/ge-is200epctg1a-ex2100-pt-ct-terminal-board","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}