{"product_id":"ge-fanuc-qph-2d100-l2p-quickpanel-hmi-terminal","title":"GE Fanuc QPH-2D100-L2P QuickPanel HMI Terminal","description":"\u003cdiv class=\"auto-hide-last-sibling-br paragraph-JOTKXA paragraph-element br-paragraph-space\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e \u003cstrong\u003eQPH-2D100-L2P\u003c\/strong\u003e is a compact 5.7-inch monochrome Human-Machine Interface (HMI) terminal within the QuickPanel series. Designed for efficient operator interaction and machine control, this unit features a 16-shade gray scale QVGA display, integrated resistive touch functionality, and dual serial interfaces. It offers a low-power, space-saving solution for machine tool setups, material handling control, and localized PLC monitoring networks.\u003c\/p\u003e\n\u003ch3\u003eVisual Display and Internal Processing Core\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eQPH-2D100-L2P\u003c\/strong\u003e incorporates a 5.7-inch monochrome LCD powered by a long-life white LED backlight rated for up to 100,000 operational hours. With a 320 x 240 pixel (QVGA) resolution and 16 levels of gray scale, the screen presents crisp text, animated symbols, and alarm statuses. An internal 32-bit RISC processor handles high-speed screen refreshing and touch responses, backed by 2 MB of Flash memory for project files and 4 MB of SDRAM for dynamic runtime data execution.\u003c\/p\u003e\n\u003ch3\u003eSerial Communication and Installation Design\u003c\/h3\u003e\n\u003cp\u003eSerial connectivity is facilitated through one dedicated RS232 port and one RS422\/485 port, enabling direct communication with GE Series 90-30, Series 90-70, and various third-party PLCs. Operating on an external 24 VDC power source with a low 10 W maximum power draw, the terminal mounts flush into control panel cutouts measuring 205 mm x 135 mm. A front-accessible 3 V lithium cell preserves real-time clock settings and volatile memory during system shutdowns.\u003c\/p\u003e\n\u003ch3\u003eSystem Mounting and Initial Configuration\u003c\/h3\u003e\n\u003cp\u003eTo install and initialize the operator terminal, adhere to the following sequence:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eCut a 205 mm x 135 mm opening into the enclosure cabinet door.\u003c\/li\u003e\n\u003cli\u003eInsert the unit from the front and fix it securely using the provided mounting clamps.\u003c\/li\u003e\n\u003cli\u003eWire a regulated 24 VDC power supply directly to the rear power terminal block.\u003c\/li\u003e\n\u003cli\u003eEstablish a communication link using the RS232 port to connect to a programming PC or target controller.\u003c\/li\u003e\n\u003cli\u003eTransfer custom screen layouts and touch assignments built using GE QuickDesigner software.\u003c\/li\u003e\n\u003cli\u003eConnect the RS422\/485 serial port to the controller network for active data acquisition.\u003c\/li\u003e\n\u003cli\u003eReplace the 3 V lithium battery whenever the low-battery warning displays on screen.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPH-2D100-L2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eQuickPanel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eMonochrome LCD with LED backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.7 inches diagonal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e320 x 240 pixels (QVGA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGray Scales\u003c\/td\u003e\n\u003ctd\u003e16 levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Panel\u003c\/td\u003e\n\u003ctd\u003eResistive analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e2 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime Memory\u003c\/td\u003e\n\u003ctd\u003e4 MB SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 x RS232, 1 x RS422\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Type \u0026amp; Life\u003c\/td\u003e\n\u003ctd\u003eWhite LED, 100,000 hours typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup\u003c\/td\u003e\n\u003ctd\u003e1 x 3 V lithium cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e220 mm x 150 mm x 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Cutout\u003c\/td\u003e\n\u003ctd\u003e205 mm x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What software package is used to build graphic projects for this terminal? A: Operator screens, alarms, and touch functions are designed and compiled using GE QuickDesigner software.\u003c\/p\u003e\n\u003cp\u003eQ: Which PLC families can communicate directly with this HMI panel? A: The panel supports communication with GE Series 90-30 and Series 90-70 controllers, as well as multiple third-party PLCs via RS232 and RS422\/485 serial connections.\u003c\/p\u003e\n\u003cp\u003eQ: How is the real-time clock powered when main system power is disconnected? A: An internal 3 V lithium cell maintains clock settings and volatile data during power outages and must be replaced when a low-battery alarm appears.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53162991550744,"sku":"QPH-2D100-L2P","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/QPH-2D100-L2P_Cocoai.jpg?v=1793936711","url":"https:\/\/www.innoplcsync.com\/products\/ge-fanuc-qph-2d100-l2p-quickpanel-hmi-terminal","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}