{"product_id":"ge-fanuc-ds200rtbag1ahc-analog-i-o-board","title":"GE Fanuc|DS200RTBAG1AHC|Analog I\/O Board","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\" data-spm-anchor-id=\"5176.28103460.0.i10.460b7551niFeFr\"\u003eGE Fanuc DS200RTBAG1AHC Analog I\/O Board\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eThe GE Fanuc DS200RTBAG1AHC is an analog input\/output (I\/O) board in the Mark V series, used for scaling and conditioning analog signals in gas turbine control systems.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eProcesses LVDT inputs, servo valve outputs, thermocouple signals, 4–20 mA I\/O, vibration inputs, relay driver outputs, pulse inputs, voltage inputs, and generator\/line signals\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eInterfaces with STCA and TCQC boards via 3PL and JE connectors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eConfigurable via hardware jumpers for output settings and diagnostics\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: DS200RTBAG1AHC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eManufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: General Electric (GE) \/ GE Fanuc\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Mark V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Analog I\/O Board (TCQA)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eCountry of Origin\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: United States\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003emA Output Range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Selectable via jumpers J5\/J6 (20 mA or 200 mA)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOutput Circuit Selection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Controlled by jumpers J1 and J2\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDiagnostics\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: RS232 test port enabled via jumper J7\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOscillator Enable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Activated by jumper J8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSignal Types Supported\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e:\u003c\/span\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003e4–20 mA input\/output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eThermocouple inputs with cold-junction compensation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003e±10 V DC inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eLVDT\/LVDR position feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePulse and relay driver signals\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eConnectors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e:\u003c\/span\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003e3PL: Links to STCA, TCQA, and TCQE on COREBUS\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eJE: Communicates generator\/line signals with TCQC board\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":51639977181464,"sku":"DS200RTBAG1AHC","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/s-l1600_3_e305db7a-87aa-4aaa-83d1-f56710a5cbd4.jpg?v=1731399946","url":"https:\/\/www.innoplcsync.com\/products\/ge-fanuc-ds200rtbag1ahc-analog-i-o-board","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}