{"product_id":"ge-fanuc-ds200qtbag1adc-analog-output-board","title":"GE Fanuc|DS200QTBAG1ADC| Analog Output Board","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\" data-spm-anchor-id=\"5176.28103460.0.i12.460b7551Z8bxig\"\u003eGE Fanuc DS3800NOAA1F1D Analog Output Board\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eThe GE Fanuc DS3800NOAA1F1D is a high-precision analog output board manufactured by General Electric for the Mark IV turbine control system, designed to convert digital control signals into regulated analog currents for actuator positioning.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDedicated 4-channel analog current output interface\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eIntegrated self-diagnostic and fault detection logic\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eRobust design for high-noise turbine environments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDirect plug-in compatibility with Mark IV backplanes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eRedundant signal path support for critical safety loops\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSystem Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: GE Mark IV Speedtronic Turbine Control System\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eBoard Type\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Analog Output Assembly (NOAA)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eChannel Count\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 4 independent isolated analog output channels\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOutput Signal Range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 4 mA to 20 mA DC standard industrial current loop\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eLoad Resistance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Maximum 600 Ohms per channel at rated output\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOutput Accuracy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Within plus or minus 0.1 percent of full scale\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 12-bit digital-to-analog conversion resolution\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eUpdate Rate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Typical signal refresh time of 5 milliseconds\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: -20 C to +65 C ambient operating range\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: -40 C to +85 C non-operating limit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePower Supply Input\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Regulated 24 VDC nominal with plus or minus 10 percent tolerance\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePower Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Approximately 3.5 Watts typical at full load\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eIsolation Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 500 VAC galvanic isolation between channels and logic\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eForm Factor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Standard Eurocard size fitting 6U rack chassis\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eConnector Type\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: High-density 96-pin DIN 41612 backplane connector\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eUnit Weight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Approximately 0.6 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":51810740928792,"sku":"DS3800NOAA1F1D","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/s-l1600_3_e305db7a-87aa-4aaa-83d1-f56710a5cbd4.jpg?v=1731399946","url":"https:\/\/www.innoplcsync.com\/products\/ge-fanuc-ds200qtbag1adc-analog-output-board","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}