{"product_id":"foxboro-p0918hu-field-bus-module","title":"Foxboro|P0918HU| Field Bus Module","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\" data-spm-anchor-id=\"5176.28103460.0.i40.460b7551TuBClf\"\u003eFOXBORO P0918HU Field Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eThe FOXBORO P0918HU is a specific Field Bus Module (FBM218) designed for the Foxboro I\/A Series Distributed Control System, functioning as an 8-channel HART communication redundant output interface for analog control signals.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eEight isolated output channels with HART capability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSupports module-level and fieldbus redundancy\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eConfigurable 4-20 mA analog output with digital overlay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eAdvanced diagnostic monitoring per channel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eCompact design for high-density installation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eModule Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output with HART Communication\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eModel Designation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eFBM218\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eChannel Count:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003e8 independent isolated channels\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOutput Signal Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003e4 mA to 20 mA DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eHART Protocol:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports FSK digital signal overlay\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eRedundancy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eDual 2 Mbps fieldbus path support (Path A\/B)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOutput Resolution:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003e16-bit digital-to-analog conversion\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eLoad Resistance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eMaximum 600 Ohms per channel at 24 VDC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eUpdate Rate:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable from 50 ms to 1000 ms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eIsolation Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003e1500 VAC channel-to-bus and channel-to-channel\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003ePlus or minus 0.1 percent of span at 25 degrees Celsius\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePower Dissipation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eMaximum 4.0 Watts typical load\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eMinus 20 degrees Celsius to plus 70 degrees Celsius\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eStorage Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eMinus 40 degrees Celsius to plus 85 degrees Celsius\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eHumidity Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003e5 percent to 95 percent non-condensing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePhysical Dimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eApprox 140 mm x 35 mm x 180 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 0.45 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eMounting:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail or specialized Foxboro carrier assembly\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eLED Indicators:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eStatus LEDs for power, comms, redundancy, and channel faults\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eCertification:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eUL, CE, FM, and CSA approved for hazardous locations\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eMean Time Between Failures:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003cspan\u003e \u003c\/span\u003eExceeds 120,000 hours under normal operation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":51822459584792,"sku":"P0918HU","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1_7.jpg?v=1756892498","url":"https:\/\/www.innoplcsync.com\/products\/foxboro-p0918hu-field-bus-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}