{"product_id":"foxboro-p0914qx-oc-fieldbus-interface-module","title":"Foxboro|P0914QX-OC| Fieldbus Interface Module","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\" data-spm-anchor-id=\"5176.28103460.0.i23.460b755109vzK4\"\u003eFOXBORO P0914QX-OC Fieldbus Interface Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eThe FOXBORO P0914QX-OC is a specialized Fieldbus Interface Module designed for the Foxboro I\/A Series DCS to enable robust FOUNDATION Fieldbus H1 communication in hazardous environments.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSupports FOUNDATION Fieldbus H1 protocol standards.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eCertified for use in hazardous locations with intrinsic safety.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eFacilitates multi-drop connection of field instruments.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eIntegrates seamlessly with Foxboro I\/A Series node processors.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eCommunication Standard\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: IEC 61158-2 FOUNDATION Fieldbus H1.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eTransmission Speed\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Fixed 31.25 kbit\/s data rate.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eChannel Count\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Single H1 segment interface per module.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDevice Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Supports up to 16 field devices per segment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Minus 40 degrees Celsius to plus 70 degrees Celsius.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Minus 40 degrees Celsius to plus 85 degrees Celsius.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eHumidity Range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 5 percent to 95 percent relative humidity non-condensing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eInput Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 24 Volts DC nominal with plus or minus 10 percent tolerance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePower Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Approximately 140 mA at 24 Volts DC typical load.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSegment Power Output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Provides up to 400 mA for field device powering.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eElectrical Isolation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 500 Volts AC isolation between field and system logic.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePhysical Form Factor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Standard I\/A Series card size fitting 15-slot chassis.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Approximate unit weight of 0.4 kilograms.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"qk-md-li\"\u003e\n\u003cstrong class=\"qk-md-strong\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSafety Certifications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e: FM, CSA, ATEX, and IECEx approved for Class I Division 2 and Zone 2.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":51737698500888,"sku":"P0914QX-OC","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/TRICONEXFBM214P0916BX_2.jpg?v=1745570031","url":"https:\/\/www.innoplcsync.com\/products\/foxboro-p0914qx-oc-fieldbus-interface-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}