{"product_id":"digital-relay-output-modules-allen-bradley-1746-ow8","title":"Digital Relay Output Modules | Allen Bradley 1746-OW8","description":"\u003cp\u003eThe Allen Bradley \u003cstrong\u003e1746-OW8\u003c\/strong\u003e is an eight-point digital relay output module designed for the SLC 500 programmable controller platform. It provides eight normally open relay contact outputs arranged in two groups of four points. The module supports AC and DC switching, with operating voltage ranges of 5-265 VAC and 5-125 VDC, respectively.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight relay contact output points.\u003c\/li\u003e\n\u003cli\u003eTwo output groups with four points per group.\u003c\/li\u003e\n\u003cli\u003eNormally open (NO) relay contacts.\u003c\/li\u003e\n\u003cli\u003eSupports AC and DC output switching.\u003c\/li\u003e\n\u003cli\u003eAC operating voltage range of 5-265 VAC.\u003c\/li\u003e\n\u003cli\u003eDC operating voltage range of 5-125 VDC.\u003c\/li\u003e\n\u003cli\u003eSpecified operating frequency of 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003eChassis-mounted installation.\u003c\/li\u003e\n\u003cli\u003eDesigned for the Allen Bradley SLC 500 product family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-OW8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1746-OW8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOutput Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eNormally Open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Groups\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoints Per Group\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e5-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e5-125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eChassis Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRelay Output Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1746-OW8 provides eight normally open relay contacts divided into two electrically organized output groups, each containing four points. When an output is activated, its corresponding relay contact closes to establish the switching path for the connected field load.\u003c\/p\u003e\n\u003cp\u003eThe normally open configuration means that the contact remains open when the relay is de-energized. This arrangement supports discrete control of external devices using either AC or DC supplies within the specified voltage ranges.\u003c\/p\u003e\n\u003ch3\u003eOutput Grouping and Wiring\u003c\/h3\u003e\n\u003cp\u003eThe two-group arrangement is an important consideration when planning field wiring. Each group contains four relay output points, so the grouping should be considered when allocating external supply circuits and connecting loads.\u003c\/p\u003e\n\u003cp\u003eThe module uses chassis mounting within the SLC 500 platform. Before installation or replacement, verify the terminal assignments, group connections, load requirements, and applicable controller chassis configuration.\u003c\/p\u003e\n\u003ch3\u003eAC and DC Switching\u003c\/h3\u003e\n\u003cp\u003eThe relay contacts support output voltages from 5-265 VAC and 5-125 VDC. The supplied product information also specifies 50\/60 Hz operation for AC applications.\u003c\/p\u003e\n\u003cp\u003eThese voltage ranges identify the supported switching conditions but do not establish the allowable current for each contact. Individual contact ratings, load characteristics, and switching limitations should be checked before connecting field devices.\u003c\/p\u003e\n\u003ch3\u003eProduct Availability and Warranty\u003c\/h3\u003e\n\u003cp\u003eThe 1746-OW8 is identified as discontinued by the manufacturer. This status is relevant when sourcing spare modules or planning maintenance for existing SLC 500 installations.\u003c\/p\u003e\n\u003cp\u003eThe supplied Radwell product listing states that the factory warranty does not apply and includes a Radwell 2-year warranty. This is a seller-provided warranty and is separate from any Allen Bradley factory warranty.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many output points and groups does the Allen Bradley 1746-OW8 have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1746-OW8 provides eight normally open relay output points arranged in two groups of four. This grouping should be considered when planning external supply connections and field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1746-OW8 control both AC and DC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The relay outputs support 5-265 VAC and 5-125 VDC. The connected loads must also comply with the applicable relay contact current and switching ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 1746-OW8 and a transistor output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1746-OW8 uses normally open relay contacts for output switching, rather than semiconductor switching devices. Its relay-based configuration supports both AC and DC loads within the specified voltage limits, subject to the applicable contact ratings.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53330507464984,"sku":"1746-OW8","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1746-IA8_Cocoai_b871ed1f-8ad7-4df3-8f2d-ddb80109f678.jpg?v=1794970877","url":"https:\/\/www.innoplcsync.com\/products\/digital-relay-output-modules-allen-bradley-1746-ow8","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}