{"product_id":"asprtu258c-schneider-electric-power-supply-module","title":"ASPRTU258C | Schneider Electric Power Supply Module","description":"\u003cp\u003eThe Schneider Electric \u003cstrong\u003eASPRTU258C\u003c\/strong\u003e is an AC-input power supply module described for Modicon PLC rack configurations. It converts incoming AC power into regulated 5 VDC and 24 VDC outputs for backplane logic, I\/O modules, relays, and communication cards. Its specified configuration includes separate output ratings, overvoltage and short-circuit protection, and 25 ms of hold-up time during brief input interruptions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Ratings and Output Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ASPRTU258C accepts a wide AC input range and supports both 50 Hz and 60 Hz supply networks. It provides two DC output rails for different system loads: 5 VDC supplies backplane logic, while 24 VDC supports output modules and associated control circuits.\u003c\/p\u003e\n\u003cp\u003eThe specified output ratings allow engineers to check the available current capacity when calculating the power requirements of a PLC rack. Output ripple is specified below 35 mV peak-to-peak at full load, while typical conversion efficiency is rated at 84%.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection and Power Continuity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module includes overvoltage protection for both DC outputs and short-circuit protection that shuts down individual outputs during wiring faults. These functions protect the power supply and connected circuitry against specified electrical fault conditions.\u003c\/p\u003e\n\u003cp\u003eThree internal electrolytic capacitors provide energy storage, with a stated hold-up time of 25 ms. This supports the DC outputs during brief AC input disturbances. It should not be treated as a substitute for an external UPS or battery backup system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Configuration and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ASPRTU258C uses a single internal PCB containing the rectification, filtering, and voltage regulation circuits. AC input wiring connects through a 4-pin screw terminal block, while an 8-pin connector delivers the DC outputs to the backplane.\u003c\/p\u003e\n\u003cp\u003eThe described cooling arrangement uses natural convection rather than forced-air cooling. Installation should therefore allow adequate airflow around the module and follow the applicable rack and enclosure requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASPRTU258C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePLC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Input\u003c\/td\u003e\n\u003ctd\u003e115\/230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 VDC Output Current\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003eBelow 35 mV peak-to-peak at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Efficiency\u003c\/td\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-up Time\u003c\/td\u003e\n\u003ctd\u003e25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage\u003c\/td\u003e\n\u003ctd\u003e3 electrolytic capacitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eOvervoltage and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal PCB Count\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Connector\u003c\/td\u003e\n\u003ctd\u003e4-pin screw terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output Connector\u003c\/td\u003e\n\u003ctd\u003e8-pin backplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eDedicated PLC rack power slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e128 x 56 x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What DC output voltages does the ASPRTU258C provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides two regulated outputs: 5 VDC at 8 A for backplane logic and 24 VDC at 2 A for associated control loads. Both ratings should be considered when checking the total power requirements of the connected configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ASPRTU258C operate with both 115 VAC and 230 VAC supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied specifications identify an operating input range of 85 to 264 VAC and a frequency range of 47 to 63 Hz. This covers typical 115 VAC and 230 VAC supply networks, although the actual wiring requirements should be checked against the module markings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ASPRTU258C provide battery backup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No external battery backup is specified. Its three internal electrolytic capacitors provide a stated 25 ms hold-up time, intended to bridge brief input disturbances rather than extended power failures.\u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":53424739025176,"sku":"ASPRTU258C","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/ASPRTU258C.png?v=1795488184","url":"https:\/\/www.innoplcsync.com\/products\/asprtu258c-schneider-electric-power-supply-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}