{"product_id":"allen-bradley-440r-em4r2d-guardmaster-emd-safety-relay","title":"Allen-Bradley 440R-EM4R2D Guardmaster EMD Safety Relay","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 440R-EM4R2D\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e440R-EM4R2D\u003c\/strong\u003e EMD Safety Relay, operates as a dedicated hardware component for safety delayed expansion and output circuit control within Guardmaster Safety Relays platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e440R-EM4R2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg (0.56 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact Guardmaster expansion housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-5 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.9 W (24 VDC input power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power-on Delay\u003c\/td\u003e\n\u003ctd\u003e7 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.4 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003ePolyamide PA 6.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eEnclosure IP40, Terminals IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e90% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility \u0026amp; Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 440R-EM4R2D expansion safety relay communicates with master safety modules via single-wire bus interfaces to execute timed drop-out delayed safety function loops. The internal micro-controller executes real-time timing sequence validation across configured delays up to 7 seconds, guaranteeing predictable fail-safe state execution during system emergency stop or light curtain trip events. Internal diagnostic monitoring across safety relay contacts ensures high backplane integrity and immunity to electrical noise transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary purpose of the maximum 7-second power-on delay?\u003c\/p\u003e\n\u003cp\u003eA: The integrated off-delay timer enables controlled deceleration or delayed output de-energization for controlled stop sequences before removing safety power.\u003c\/p\u003e\n\u003cp\u003eQ: What torque rating should be applied when terminating control wiring?\u003c\/p\u003e\n\u003cp\u003eA: All terminal block screws must be torqued to precisely 0.4 Nm to maintain IP20 electrical connection security and prevent wire loosening under vibration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect and isolate the 24 VDC control power source before attaching or removing terminal connections on the safety relay block.\u003c\/li\u003e\n\u003cli\u003eMount the Polyamide PA 6.6 enclosure on a standard 35 mm DIN rail inside an IP54-rated control enclosure to maintain the required IP40 chassis protection.\u003c\/li\u003e\n\u003cli\u003eKeep single-wire safety bus connections and output circuit cables segregated from AC power wiring, VFD output cables, and high-current inductive loads.\u003c\/li\u003e\n\u003cli\u003eEnsure the cabinet environment remains within -5 deg C to +55 deg C and non-condensing relative humidity stays below 90% to prevent internal moisture tracking.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52827344240920,"sku":"440-EM4R2D","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/440-EM4R2D2_Cocoai.jpg?v=1791427254","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-440r-em4r2d-guardmaster-emd-safety-relay","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}