{"product_id":"allen-bradley-2711p-t6m8a-hmi-operator-terminals","title":"Allen-Bradley 2711P-T6M8A HMI Operator Terminals","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711P-T6M8A\u003c\/strong\u003e serves as the primary \u003cstrong\u003e2711P\u003c\/strong\u003e PanelView Plus 600 Terminal utilized to execute graphical operator interface functions and control inputs across industrial control network platforms. Operating on an internal 100-240 V AC power supply, it processes visualization tasks using an onboard 200 MHz processor while managing multi-node data transfer across RS-232, Ethernet, and DH+ communication networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T6M8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.47 kg (3.25 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PanelView Plus 600 enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC (70 VA maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.5 in Monochrome Grayscale (320 x 240 pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Mechanism\u003c\/td\u003e\n\u003ctd\u003eAnalog Resistive Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, Ethernet, DH+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port Isolation\u003c\/td\u003e\n\u003ctd\u003e50 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP \u0026amp; Backplane Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 2711P-T6M8A panel terminal leverages dedicated communication processing to manage deterministic data framing across Ethernet, RS-232, and legacy DH+ networks. The onboard 200 MHz processor optimizes task execution and graphics rendering while maintaining continuous backplane data exchange. Direct register access to controller data files eliminates redundant ladder logic routines, preserving bus bandwidth and maintaining consistent screen refresh rates across interconnected nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What operating voltage is required for the 2711P-T6M8A terminal?\u003c\/p\u003e\n\u003cp\u003eA: The terminal integrates an AC power supply accepting an input line voltage range of 100-240 V AC (70 VA maximum power consumption).\u003c\/p\u003e\n\u003cp\u003eQ: What level of electrical isolation is provided on the serial communication port?\u003c\/p\u003e\n\u003cp\u003eA: The onboard serial port features galvanic isolation rated against continuous voltage differentials up to 50 V DC to protect circuitry from common-mode electrical noise.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the primary 100-240 V AC line power source prior to terminating wiring on the main terminal block to prevent electrical shock or arc flash.\u003c\/li\u003e\n\u003cli\u003ePrepare the enclosure cutout to exact panel dimensions and torque the mounting clips sequentially to maintain uniform gasket pressure for environmental sealing.\u003c\/li\u003e\n\u003cli\u003eRoute RS-232, Ethernet, and DH+ communication lines away from high-current AC motor leads and drive outputs, maintaining a minimum spacing of 200 mm.\u003c\/li\u003e\n\u003cli\u003eEarth ground the chassis ground terminal and communication cable shielding to a central busbar to ensure effective noise rejection and maintain 50 V DC port isolation limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52827338637592,"sku":"2711P-T6M8A","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/2711P-T6M5A2_Cocoai_d3e1b355-ab17-4e46-a9d9-35c957685428.jpg?v=1791427215","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-2711p-t6m8a-hmi-operator-terminals","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}