{"product_id":"allen-bradley-2711-t6c5l1-panelview-600-operator-interface","title":"Allen-Bradley 2711-T6C5L1 PanelView 600 Operator Interface","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711-T6C5L1\u003c\/strong\u003e serves as the primary \u003cstrong\u003e2711-T6C5L1\u003c\/strong\u003e Operator Interface utilized to execute process visualization and touch command entry across Allen-Bradley automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T6C5L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.86 kg (1.90 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PanelView 600 cutout panel format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (18-30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e5.7-inch color active matrix display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e320 x 234 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Input\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRS-232 port supporting DH-485 protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and EtherNet\/IP Mapping\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 2711-T6C5L1 maintains serial point-to-point and multi-node telemetry over its dedicated RS-232 interface using DH-485 protocol framing. Onboard firmware flash compatibility ensures rapid frame processing and synchronous memory address mapping between touchscreen input registers and connected controller data tables. This deterministic message handling prevents packet collisions on serial links and maintains real-time updates for process graphics, system alarms, and bit-level interlocks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply parameters are required for the 24 VDC terminal connection on the 2711-T6C5L1?\u003c\/p\u003e\n\u003cp\u003eA: The module requires a nominal 24 VDC input within an operational range of 18 to 30 VDC. The circuit must be powered by a Class 2 safety-isolated DC supply to prevent ground loop currents from interfering with serial logic.\u003c\/p\u003e\n\u003cp\u003eQ: How is the RS-232 DH-485 communication port wired to an SLC 500 or MicroLogix controller?\u003c\/p\u003e\n\u003cp\u003eA: Connections require an appropriate point-to-point serial cable (such as 2711-NC13) or an AIC+ Advanced Interface Converter module when bridging to a multi-node DH-485 network trunk.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePrepare the panel mounting cutout to exact standard dimensions, ensuring the surface is deburred, clean, and flat.\u003c\/li\u003e\n\u003cli\u003eInsert the unit into the opening and secure all rear mounting clamps evenly in an alternating cross-pattern to establish NEMA-rated perimeter sealing.\u003c\/li\u003e\n\u003cli\u003eWire the 24 VDC power conductors to the terminal block, ensuring correct polarity and connecting the frame earth ground terminal directly to cabinet ground.\u003c\/li\u003e\n\u003cli\u003eRoute serial communication cabling through dedicated low-voltage wireways away from high-voltage AC lines and variable frequency drives.\u003c\/li\u003e\n\u003cli\u003eProvide at least 50 mm of clear ventilation space around all cabinet heatsink louvers to allow natural convection thermal cooling.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52755617120536,"sku":"2711-T6C5L1","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/2711-T6C9L12_Cocoai_082862c6-a2fc-4c97-b6e9-8fbac5511f7f.jpg?v=1790216252","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-2711-t6c5l1-panelview-600-operator-interface","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}