{"product_id":"allen-bradley-2711-t6c3l1-panelview-600-operator-interface-terminal","title":"Allen-Bradley 2711-T6C3L1 PanelView 600 operator interface terminal","description":"\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e2711-T6C3L1\u003c\/strong\u003e is a discontinued PanelView Standard 600 operator interface terminal featuring a 5.7-inch color touch screen display. Designed to interface with industrial automation machinery, this HMI unit enables operators to monitor process values, interact with control logic, and manage system operations via direct data table access.\u003c\/p\u003e\n\u003ch3\u003eDisplay and Operator Input\u003c\/h3\u003e\n\u003cp\u003eThe unit incorporates an active-matrix TFT color display with a resolution of 320 x 234 pixels. Operator inputs are managed through an analog-resistive touch screen overlay, offering tactile interaction points for selecting objects, entering data, and navigating runtime screens within industrial environments.\u003c\/p\u003e\n\u003ch3\u003eCommunication and Connectivity\u003c\/h3\u003e\n\u003cp\u003eEquipped with built-in DH-485 communication ports and an RS-232 printer port, the terminal supports point-to-point communication with single controllers or multi-node networking over a DH-485 link. This native connectivity minimizes the requirement for complex ladder logic when connecting directly to compatible controller platforms.\u003c\/p\u003e\n\u003ch3\u003ePower and Mechanical Specifications\u003c\/h3\u003e\n\u003cp\u003ePowered by an 18 to 32 VDC input voltage range, the module integrates internal circuitry designed to protect against reverse polarity and overvoltage conditions. The physical assembly is engineered for panel-mount installation, utilizing standard mounting clips and a sealing gasket to achieve a secure fit inside industrial enclosures.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T6C3L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView 600 (Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.7 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor Active Matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e320 x 234 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eTouch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDH-485, RS-232 Printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e18 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.07 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What communication protocols does the 2711-T6C3L1 support?\u003c\/p\u003e\n\u003cp\u003eA: It supports DH-485 network communication and features an RS-232 printer port for peripheral connectivity.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply is required to operate this HMI terminal?\u003c\/p\u003e\n\u003cp\u003eA: It requires an external DC power source ranging from 18 to 32 VDC (24 VDC nominal).\u003c\/p\u003e\n\u003cp\u003erface visualization and plant-floor data exchange within industrial control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-B7C6D1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e356 mm x 279 mm x 203 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 W maximum (2.9 A at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor active-matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e64 MB non-volatile flash \/ RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDH+, DH-485, RS-232, and USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe terminal facilitates real-time data monitoring through high-speed backplane bus communication protocols and deterministic network links. It executes screen navigation and tag updates by polling connected programmable logic controllers over Data Highway Plus (DH+) and DH-485 communication channels, as well as industrial serial and USB buses. Backplane bus communication velocity and I\/O density scaling ensure synchronized alarm handling, user input validation, and graphical status rendering across distributed automation topologies without introducing packet latency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the backlight assembly on this display be replaced in the field?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the internal display backlight assembly, designated as part number 2711P-RL7C2, is field-replaceable using authorized maintenance procedures after isolating system power.\u003c\/p\u003e\n\u003cp\u003eQ: How is runtime application memory managed on this terminal?\u003c\/p\u003e\n\u003cp\u003eA: Runtime application files are stored in internal non-volatile flash memory or loaded via removable storage media inserted into the side-access storage slot.\u003c\/p\u003e\n\u003cp\u003eQ: What DC input voltage range is acceptable for continuous operation?\u003c\/p\u003e\n\u003cp\u003eA: The terminal requires a 24 VDC nominal power supply, operating continuously within an input voltage range of 18 to 32 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCut out the panel mounting aperture strictly according to manufacturer dimensional templates to ensure proper gasket compression and NEMA seal integrity.\u003c\/li\u003e\n\u003cli\u003eSecure the unit into the enclosure using all mounting clips tightened evenly around the perimeter of the display bezel.\u003c\/li\u003e\n\u003cli\u003eConnect DH+ and DH-485 communication cables using appropriate shielded twinaxial media, terminating shield drains correctly at the system ground bus.\u003c\/li\u003e\n\u003cli\u003eVerify that supply voltage boundaries match the 18-32 VDC rating and ensure proper polarity prior to energizing the terminal input wiring blocks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52949111046424,"sku":"2711-T6C3L1","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/2711-T9A3_Cocoai_fbdb5ded-393c-4c27-bdc8-8bc9fc9c27cc.jpg?v=1792460203","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-2711-t6c3l1-panelview-600-operator-interface-terminal","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}