{"product_id":"allen-bradley-2711-t6c10l1-panelview-600-operator-interfaces","title":"Allen-Bradley 2711-T6C10L1 PanelView 600 Operator Interfaces","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711-T6C10L1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711-T6C10L1\u003c\/strong\u003e Operator Interface, operates as a dedicated hardware component for human-machine visualization and control input execution within DeviceNet and RS-232 serial networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T6C10L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.01 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e152 mm x 185 mm x 82 mm (6.0 in. x 7.28 in. x 3.20 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 W maximum (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e5.7-inch Active Matrix TFT Color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e320 x 234 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Resistive Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Communication Port, RS-232 Printer Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB Application Flash Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 12, 13, 4X (Indoor) \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by Manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; Deterministic Network Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 2711-T6C10L1 PanelView 600 terminal communicates across deterministic DeviceNet fieldbus channels to exchange real-time tag data, alarms, and setpoint updates directly with PLC-5, SLC 500, and ControlLogix processors. The onboard DeviceNet port supports explicit and I\/O messaging profiles at communication velocities up to 500 Kbps. An independent RS-232 serial port enables asynchronous output for alarm printing and diagnostic logging. Internal firmware flash compatibility supports rapid application downloading via PanelBuilder32 software, maintaining deterministic cycle times and high I\/O density scaling across distributed motor control centers and machine automation platforms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the input supply voltage requirement for the 2711-T6C10L1 terminal?\u003c\/p\u003e\n\u003cp\u003eA: The 2711-T6C10L1 requires a 24 VDC power supply operating within an allowable input range of 18 VDC to 32 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 2711-T6C10L1 touchscreen glass assembly be hot-swapped while power is applied?\u003c\/p\u003e\n\u003cp\u003eA: No. Main 24 VDC control power and DeviceNet bus connections must be completely isolated before disconnecting or installing the terminal to prevent internal component damage and communication bus disruption.\u003c\/p\u003e\n\u003cp\u003eQ: How is application runtime data preserved during a main power loss?\u003c\/p\u003e\n\u003cp\u003eA: Application files, display screen graphics, and system parameters are saved directly to onboard nonvolatile flash memory, retaining configuration integrity without requiring a back-up battery during power outages.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003ePrepare a rectangular panel cutout measuring 123 mm x 156 mm (4.86 in. x 6.15 in.) in a NEMA 4X or IP65 rated enclosure wall. Insert the 2711-T6C10L1 terminal through the front cutout, making sure the sealing gasket is correctly positioned around the outer bezel perimeter to maintain environmental ingress protection.\u003c\/p\u003e\n\u003cp\u003eSecure the unit using the included mounting clips, tightening screws evenly in a cross pattern to a torque spec of 1.1 Nm to 1.4 Nm (10 in-lbs to 12 in-lbs). Connect the 24 VDC supply leads using copper conductors rated for at least 75 deg C, maintaining proper terminal polarity (+24 VDC and DC Common). Bond the terminal grounding lug to the main enclosure earth ground bar using a low-impedance grounding strap.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52836511678744,"sku":"2711-T6C10L1","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/2711-T6C9L12_Cocoai_314be272-0c55-4832-b38b-cdcd4f67f6f0.jpg?v=1791512040","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-2711-t6c10l1-panelview-600-operator-interfaces","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}