{"product_id":"allen-bradley-2711-t5a16l1-panelview-550-standard-operator-terminals","title":"Allen-Bradley 2711-T5A16L1 PanelView 550 Standard Operator Terminals","description":"\u003cp\u003eConfigured for local operator monitoring and control tasks in PanelView automation networks, the \u003cstrong\u003eAllen-Bradley 2711-T5A16L1\u003c\/strong\u003e (\u003cstrong\u003e2711-T5A16L1\u003c\/strong\u003e Touch Operator Terminal) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2711: PanelView 500\/550 Operator Terminal Series\u003c\/li\u003e\n\u003cli\u003eT: Touchscreen input type\u003c\/li\u003e\n\u003cli\u003e5: 5.5-inch monochrome display format\u003c\/li\u003e\n\u003cli\u003eA: Allen-Bradley DF1 communication interface\u003c\/li\u003e\n\u003cli\u003e16: Specific communication and hardware identifier matrix\u003c\/li\u003e\n\u003cli\u003eL1: Series and firmware configuration identifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T5A16L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ Authorized Manufacturing Facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.19 lbs (0.99 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDisplay area: 120 x 60 mm (4.75 x 2.38 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C (32 deg F to 131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 W (69 BTU\/HR maximum heat dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size \u0026amp; Type\u003c\/td\u003e\n\u003ctd\u003e5.5 in. Monochrome LCD blue mode with LED backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen Resolution\u003c\/td\u003e\n\u003ctd\u003e256 x 128 pixels (128 touch cells, 16 columns x 8 rows)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e170 KB application runtime; 240 KB nonvolatile RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12\/13, 4X (Indoor use), IP54, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRS-232 (DF1) and RS-232 Printer\/Download Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Technical Architecture\u003c\/h3\u003e\n\u003cp\u003eDesigned for deterministic industrial environments, this unit integrates backplane bus communication velocity licences and supports Profinet \/ EtherNet\/IP deterministic networks via its peripheral expansion options. The I\/O density scaling and firmware flash compatibility allow seamless integration into legacy Allen-Bradley PLC architectures. The terminal executes operator commands and transfers runtime data across high-speed control networks with minimal communication latency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 2711-T5A16L1 terminal be hot-swapped while the control system is powered on?\u003c\/p\u003e\n\u003cp\u003eA: No. Power must be completely isolated and disconnected before replacing or servicing the terminal to prevent backplane bus corruption and transient voltage damage to the communication transceiver.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum backplane current draw and load limit on the 24 VDC power input?\u003c\/p\u003e\n\u003cp\u003eA: The terminal operates within an input voltage range of 18 to 30 VDC with a maximum power dissipation of 20 Watts (69 BTU\/HR). External power supplies must be adequately sized to account for inrush current during initial power-up.\u003c\/p\u003e\n\u003cp\u003eQ: Can the application runtime memory be upgraded beyond the factory baseline?\u003c\/p\u003e\n\u003cp\u003eA: The internal application runtime memory is fixed at 170 KB with 240 KB nonvolatile RAM, but storage configurations depend strictly on the hardware series version.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure panel cutouts match the precise dimensional tolerances required for the PanelView 550 housing to maintain the NEMA Type 12\/13, 4X, IP54, and IP65 environmental seals.\u003c\/li\u003e\n\u003cli\u003eProvide adequate clearance around the rear chassis and ventilation grills to prevent thermal accumulation, keeping ambient operating temperatures strictly between 0 deg C and 55 deg C.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 VDC power supply to the designated terminal block, ensuring proper polarity and verifying that input voltage does not exceed the 18 to 30 VDC threshold.\u003c\/li\u003e\n\u003cli\u003eTerminate the communication cable shield at the designated grounding lug to suppress electromagnetic interference (EMI) and ensure stable network signal propagation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52883364086040,"sku":"2711-T5A16L1","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/2711-T6C9L1_Cocoai_caa1b543-b532-4748-ae16-54178d12e484.jpg?v=1791943262","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-2711-t5a16l1-panelview-550-standard-operator-terminals","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}