{"product_id":"allen-bradley-2711-t10g3l1-panelview-1000-operator-terminal","title":"Allen Bradley 2711-T10G3L1 PanelView 1000 Operator Terminal","description":"\u003cp\u003eThe \u003cstrong\u003eAllen Bradley 2711-T10G3L1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711-T10G3L1\u003c\/strong\u003e Operator Terminal, operates as a dedicated human-machine interface hardware component for process command input and display visualization within DH-485 industrial communication networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T10G3L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in technical documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.95 lbs (2.70 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PanelView 1000 physical chassis profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C (32 to 131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC power requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eGrayscale Active Matrix Thin-Film Resistor (TFT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.0 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eDH-485, RS-232 (Printer port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12, 13, or 4X (indoor use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Deterministic Network Communication\u003c\/h3\u003e\n\u003cp\u003eThe terminal executes local firmware environments stored in nonvolatile flash memory, supporting runtime firmware flash updates via communication links. DH-485 communication protocols maintain token-passing deterministic network behavior across multi-node controller configurations, ensuring predictable message delivery intervals for operator control commands and alarm registers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the nominal input voltage required for the 2711-T10G3L1 terminal?\u003c\/p\u003e\n\u003cp\u003eA: The unit operates on a direct current supply voltage of 24 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Which legacy network protocol is natively supported by the communication port on this model?\u003c\/p\u003e\n\u003cp\u003eA: The terminal integrates a native DH-485 communication interface for peer-to-peer data exchange with compatible programmable controllers.\u003c\/p\u003e\n\u003cp\u003eQ: What type of display technology is used for visual output?\u003c\/p\u003e\n\u003cp\u003eA: It utilizes a grayscale active-matrix TFT display with a resolution of 640 x 480 pixels across a 10-inch viewing area.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePanel Cutout and Mounting: Secure the unit into the enclosure cutout using the provided mounting clips to maintain structural stability and environmental sealing.\u003c\/li\u003e\n\u003cli\u003ePower Connections: Wire the 24 VDC input terminals ensuring correct polarity, and establish a low-impedance earth ground connection.\u003c\/li\u003e\n\u003cli\u003eCable Separation: Route DH-485 communication cables and RS-232 serial cables away from high-voltage power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53000914665752,"sku":"2711-T10G3L1","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/2711-T9A3_Cocoai_0c8ea020-f52e-4012-9a1c-bebff6ce593d.jpg?v=1792725831","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-2711-t10g3l1-panelview-1000-operator-terminal","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}