{"product_id":"allen-bradley-1784-pcmk-pcmcia-communication-card","title":"Allen-Bradley 1784-PCMK PCMCIA Communication Card","description":"\u003cp\u003eThe \u003cstrong\u003e1784-PCMK\u003c\/strong\u003e is a PCMCIA Type II communication card from Allen-Bradley that allows a notebook computer to communicate with industrial controllers over DH+, DH-485, and Remote I\/O networks. It provides a 68-pin PC Card interface and operates from a 5 VDC host supply. Available in Series A and Series B versions, the card requires correct series identification when selecting replacement hardware and communication cables.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Network Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1784-PCMK provides a communication interface between a host computer and compatible Allen-Bradley control equipment. It supports Data Highway Plus (DH+) and DH-485 communication, allowing programming computers and maintenance workstations to access supported controller networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries B\u003c\/strong\u003e adds Remote I\/O scanner capabilities, 16-bit operation, updated drivers, and DH+ communication at 230 kbit\/s. These enhancements distinguish Series B from the earlier Series A card and should be considered when replacing an existing communication interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePCMCIA Interface and Power Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe card uses a PCMCIA Type II form factor with a 68-pin connector for installation in a compatible notebook computer. The host computer must support PCMCIA Card and Socket Services Standard Version 2.1. The 5 VDC supply is drawn from the host card slot, with a specified current requirement of 160 mA.\u003c\/p\u003e\n\u003cp\u003eThe PCMCIA connector interfaces with the computer, while a separate communication cable connects the card to the target controller or network. Cable selection must match both the card series and the controller communication port.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1784-PCMK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePCMCIA Communication Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard Series\u003c\/td\u003e\n\u003ctd\u003eSeries A \/ Series B (must be specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003ePCMCIA Type II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Connector\u003c\/td\u003e\n\u003ctd\u003e68-pin PC Card connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCMCIA Compliance\u003c\/td\u003e\n\u003ctd\u003ePCMCIA Card and Socket Services Standard Version 2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eDH+, DH-485, Remote I\/O (series-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries B Data Width\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries B DH+ Communication Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 230 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries B Remote I\/O Function\u003c\/td\u003e\n\u003ctd\u003eScanner capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e0.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.73 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eOpen-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 1784-PCMK Series A and Series B cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Series B provides a 16-bit interface, updated drivers, support for DH+ communication at 230 kbit\/s, and Remote I\/O scanner capabilities. It also uses a newer range of communication cables with locking connectors. Series A and Series B cable assemblies are not interchangeable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which communication cable is required for an SLC 5\/03 or SLC 5\/04 processor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For a Series B card, the SLC 5\/03 uses the 1784-PCM4\/B cable, while the SLC 5\/04 uses the 1784-PCM6\/B cable. Confirm the PCMK series and controller communication port before ordering the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1784-PCMK support Remote I\/O scanning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Series B includes Remote I\/O scanner capabilities. However, the Rockwell Automation manual lists the 1784-PCMS\/A cable for Remote I\/O connections as a demonstration configuration. Confirm the intended application and software requirements before relying on this interface for a production Remote I\/O installation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53424676110616,"sku":"1784-PCMK","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1784-PCMK_Cocoai.jpg?v=1795483712","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-1784-pcmk-pcmcia-communication-card","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}