{"product_id":"allen-bradley-1746-ob6ei-dc-output-module","title":"Allen-Bradley 1746-OB6EI DC Output Module","description":"\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1746-OB6EI\u003c\/strong\u003e is a six-point, 24 VDC electronically protected sourcing output module for the SLC 500 PLC system. It provides individually isolated transistor outputs for controlling DC field devices, with a continuous output rating of 2.0 A per point. Its built-in thermal protection responds to short-circuit and overload conditions, while its fast turn-off design supports inductive load switching.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Signal Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1746-OB6EI provides six sourcing DC transistor outputs with individual channel-to-channel isolation. In a sourcing configuration, each output supplies positive DC voltage to the connected field load, with the load circuit returning through its corresponding DC common connection.\u003c\/p\u003e\n\u003cp\u003eThe module supports a 10 to 30 VDC operating range. Individual channel isolation allows the output circuits to be configured independently, which is useful when interfacing field devices with separate DC supply circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFast Turn-Off Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1746-OB6EI incorporates suppression circuitry to reduce turn-off time when switching inductive DC loads. Rockwell Automation identifies this as a fast turn-off feature compared with standard DC output modules.\u003c\/p\u003e\n\u003cp\u003eAn additional suppression device connected across the load can defeat this fast turn-off characteristic. The load circuit and any series-connected contacts should therefore be considered when designing the output wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-OB6EI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eElectronically Protected Sourcing DC Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital DC Transistor Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eSourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current per Point\u003c\/td\u003e\n\u003ctd\u003e2.0 A at 0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current per Module\u003c\/td\u003e\n\u003ctd\u003e12.0 A at 0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e46 mA at 5 VDC; 0 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Delay (Resistive Load)\u003c\/td\u003e\n\u003ctd\u003eON: 1.0 ms; OFF: 2.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.0 V at 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surge Current per Point\u003c\/td\u003e\n\u003ctd\u003e4.0 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surge Current per Module\u003c\/td\u003e\n\u003ctd\u003e24.0 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Protection\u003c\/td\u003e\n\u003ctd\u003eThermal cut-out with automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.70 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of output does the 1746-OB6EI provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides six individually isolated sourcing DC transistor outputs. Each channel supplies positive DC voltage to its connected field load and operates within the specified 10 to 30 VDC range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the electronic protection work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module uses thermal cut-out protection to limit current during short-circuit or overload conditions. The affected channel can automatically reset after cooling. External circuit protection is still required because the electronic protection does not cover reverse polarity or AC wiring faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1746-OB6EI switch inductive loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It incorporates fast turn-off suppression for inductive DC loads. However, adding an external suppression device across the load can defeat this feature, so the wiring arrangement should be checked before installation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53424693477656,"sku":"1746-OB6EI","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1746-IG162_Cocoai_ba713fba-6f49-464c-be88-0055308a7440.jpg?v=1795484503","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-1746-ob6ei-dc-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}