{"product_id":"allen-bradley-1746-ob16e-output-module","title":"Allen-Bradley 1746-OB16E Output Module","description":"\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1746-OB16E\u003c\/strong\u003e is a 16-point digital DC sourcing output module for the SLC 500 PLC platform. It operates with a 10 to 30 VDC field supply and provides electronically protected transistor outputs for controlling DC loads. Its thermal cut-out protection responds to short-circuit and overload conditions, while the module supports a maximum continuous output current of 8.0 A.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1746-OB16E provides 16 sourcing transistor outputs, with all 16 points connected to a common supply arrangement. In a sourcing configuration, each activated output supplies positive DC current to its connected field device.\u003c\/p\u003e\n\u003cp\u003eThe module supports 12 VDC and 24 VDC load applications within its specified operating voltage range. Its removable terminal block provides access to the field wiring connections, allowing output circuits to be connected to compatible DC loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectronic Short-Circuit Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1746-OB16E incorporates electronic overload protection based on a thermal cut-out principle. When a short circuit or overload occurs, the affected channel limits its current after reaching the protection temperature, while the remaining channels continue operating according to the processor commands.\u003c\/p\u003e\n\u003cp\u003eThe module includes an \u003cstrong\u003eE-Fuse LED\u003c\/strong\u003e to indicate output short-circuit or overload conditions. Following correction of the fault and sufficient cooling, the affected channel can automatically reset and resume operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Current and Load Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports up to 1.0 A continuous current per point at 30 deg C and 0.5 A per point at 60 deg C. The maximum continuous current for the entire module is 8.0 A across the 0 to 60 deg C operating range. These limits must be considered together when distributing loads across the 16 output channels.\u003c\/p\u003e\n\u003cp\u003eThe electronic protection responds differently depending on the number of adjacent channels under load. Rockwell Automation identifies four protection groupings: channels 0-3, 4-7, 8-11, and 12-15. Loading multiple adjacent channels can cause the thermal protection threshold to be reached at a lower overload current.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFast Turn-Off Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1746-OB16E provides reduced inductive-load turn-off time on \u003cstrong\u003eSeries B and later hardware versions\u003c\/strong\u003e. Rockwell Automation specifies approximately 70% faster inductive-load turn-off compared with standard DC output modules.\u003c\/p\u003e\n\u003cp\u003eThis feature is relevant when switching inductive devices such as DC contactors and solenoid loads. Additional suppression components across the load can affect the fast turn-off characteristic, so the manufacturer's wiring recommendations should be followed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-OB16E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eElectronically Protected DC Sourcing Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule ID Code\u003c\/td\u003e\n\u003ctd\u003e2920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDigital Transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eSourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoints per Common\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e135 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current per Point\u003c\/td\u003e\n\u003ctd\u003e1.0 A at 30 deg C; 0.5 A at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Current per Module\u003c\/td\u003e\n\u003ctd\u003e8.0 A at 0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.0 V at 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surge Current per Point\u003c\/td\u003e\n\u003ctd\u003e2.0 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Delay (Resistive Load)\u003c\/td\u003e\n\u003ctd\u003eON: 1.0 ms; OFF: 1.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Protection\u003c\/td\u003e\n\u003ctd\u003eThermal cut-out, short-circuit and overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Recovery\u003c\/td\u003e\n\u003ctd\u003eAutomatic reset after cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Indicator\u003c\/td\u003e\n\u003ctd\u003eE-Fuse LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eRemovable Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Turn-Off\u003c\/td\u003e\n\u003ctd\u003eSeries B and later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.73 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1746-OB16E have built-in short-circuit protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It uses electronic thermal cut-out protection to limit current during output short-circuit and overload conditions. The affected channel can automatically reset after the overload is corrected and the channel cools sufficiently. This protection does not replace external fuses or circuit breakers and does not protect against reverse-polarity or AC wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum output current of the 1746-OB16E?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports a maximum continuous current of 1.0 A per point at 30 deg C and 0.5 A per point at 60 deg C. Total continuous module current must not exceed 8.0 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does every 1746-OB16E support fast inductive-load switching?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The reduced inductive-load turn-off feature is specified for Series B and later hardware versions. Since the hardware revision is not identified by the catalog number alone, verify the module nameplate before relying on this feature.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53424692101400,"sku":"1746-OB16E","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1746-OB32E_Cocoai.jpg?v=1795484284","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-1746-ob16e-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}