{"product_id":"allen-bradley-1746-nio4i-slc-500-analog-i-o-module","title":"Allen Bradley 1746-NIO4I SLC 500 Analog I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen Bradley 1746-NIO4I\u003c\/strong\u003e is a high-resolution combination analog I\/O module for the SLC 500 programmable controller platform. It provides two analog input channels supporting voltage and current signals, together with two analog current output channels. Its 16-bit resolution supports analog signal acquisition and output control in applications requiring higher-resolution data handling.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Input Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides two analog input channels, supporting selectable signal types of +\/-10 VDC and 0-20 mA, as identified in the supplied product description. These inputs allow the SLC 500 controller to acquire voltage or current signals from compatible field instruments.\u003c\/p\u003e\n\u003cp\u003eThe 16-bit resolution determines the digital representation of the measured analog signal. The selected input signal type and corresponding engineering range should be considered when configuring the PLC application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Output Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1746-NIO4I also provides two analog current output channels with a specified range of 0-20 mA. The PLC processor supplies output values through the module, which converts digital commands into corresponding analog current signals for compatible field devices.\u003c\/p\u003e\n\u003cp\u003eThe combination of analog inputs and current outputs allows one module to handle both signal acquisition and analog command generation. This configuration provides four analog channels in total.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Installation Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is designed for rack mounting in the SLC 500 system. Its listed bus current requirements are 55 mA at 5 VDC and 90 mA at 24 VDC. These values should be considered when checking the available power budget of the chassis.\u003c\/p\u003e\n\u003cp\u003eThe specified operating temperature range is 0 to 60 deg C. The module is identified as discontinued by the manufacturer, so replacement selection should account for its mixed voltage\/current input configuration and dual current output channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-NIO4I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCombination Analog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Configuration\u003c\/td\u003e\n\u003ctd\u003e2 Analog Inputs \/ 2 Analog Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Analog Points\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e+\/-10 VDC \/ 0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Signal\u003c\/td\u003e\n\u003ctd\u003e0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Draw at 5 VDC\u003c\/td\u003e\n\u003ctd\u003e55 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Draw at 24 VDC\u003c\/td\u003e\n\u003ctd\u003e90 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e21 A Max (as listed; rating definition requires confirmation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eRack Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eRadwell 2-year warranty included; factory warranty does not apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What analog signals can the 1746-NIO4I accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides two analog inputs supporting +\/-10 VDC and 0-20 mA signals. The appropriate signal type must match the connected field device and module configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of analog outputs does the 1746-NIO4I provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides two analog current output channels, each specified for a 0-20 mA signal range. These outputs allow the PLC to send analog current commands to compatible external equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when selecting a replacement for the 1746-NIO4I?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the two-input\/two-output configuration, 16-bit resolution, input signal types, 0-20 mA output range, and SLC 500 chassis requirements. Also check the available 5 VDC and 24 VDC bus current capacity before installing a replacement.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53357209157912,"sku":"1746-NIO4I","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1746-NIO4I2_Cocoai_1_af79ca1c-5bf2-4363-b13d-345e7fb5bf03.jpg?v=1795140533","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-1746-nio4i-slc-500-analog-i-o-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}