{"product_id":"allen-bradley-1606-xls480e-3-industrial-power-supply","title":"Allen-Bradley 1606-XLS480E-3 Industrial Power Supply","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1606-XLS480E-3\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1606-XLS480E-3\u003c\/strong\u003e Power Supply, operates as a dedicated hardware component for converting three-phase AC input into regulated 24-28 VDC power delivery within industrial control panels and automation networks. It directly feeds PLC racks, field actuators, and control electronics while delivering a 480 W rated output with 150% power boost capability to absorb transient inductive load spikes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1606-XLS480E-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.01 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-Rail Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C (-13 to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e480 W rated output (up to 150% peak power boost)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 480 VAC (Three-Phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 28 VDC (Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003e1606-XLS Performance Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e95% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eEngineered for seamless integration alongside high-density control chassis, the unit ensures deterministic power stability across backplane bus communication networks. The ultra-high efficiency rating of 95% reduces cabinet thermal loading, preventing voltage sag during peak system operations or firmware flash execution across adjacent I\/O modules. Integrated current sharing allows parallel operation configurations to scale overall power capacity or establish N+1 redundancy across high-availability automation racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 1606-XLS480E-3 accommodate high-inrush field loads?\u003c\/p\u003e\n\u003cp\u003eA: The power supply provides a 150% peak power boost capability, allowing it to deliver short-term extra current without dropping output voltage when driving heavy inductive loads like field relays, DC motors, or solenoids.\u003c\/p\u003e\n\u003cp\u003eQ: Can multiple 1606-XLS480E-3 units be connected in parallel for redundant operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports parallel operation mode. When installed with appropriate decoupling diodes, multiple units can be wired together to build N+1 redundant power supply topologies or increase total load output.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the power supply vertically on a standard 35 mm DIN rail inside a ventilated electrical control cabinet.\u003c\/li\u003e\n\u003cli\u003eEnsure minimum clearance distances (typically 40 mm top, 20 mm bottom, and 5 mm lateral) around the perforated housing to facilitate natural thermal convection.\u003c\/li\u003e\n\u003cli\u003eWire the three-phase AC mains (380 to 480 VAC) to the primary terminal block with proper phase rotation and earth grounding.\u003c\/li\u003e\n\u003cli\u003eAdjust the front-panel potentiometer to set the target DC output voltage (24 to 28 VDC) prior to connecting active control loads.\u003c\/li\u003e\n\u003cli\u003eUtilize properly sized copper conductors and strain-relief cable management to prevent terminal connection stress.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52693113372952,"sku":"1606-XLS480E-3","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1606-XLS480E-31_Cocoai.jpg?v=1789611914","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-1606-xls480e-3-industrial-power-supply","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}