{"product_id":"allen-bradley-100-fsv136-surge-suppressor-module","title":"Allen-Bradley 100-FSV136 Surge Suppressor Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 100-FSV136\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e100-FSV136\u003c\/strong\u003e Surge Suppressor Module, operates as a dedicated hardware component for transient voltage clamping and coil protection within control relay and contactor circuits. Mounted directly across control coil terminals, it suppresses inductive voltage spikes produced during coil de-energization to protect solid-state digital outputs and backplane bus communication velocity across Allen-Bradley control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e100-FSV136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 lbs (0.023 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact Contactor-Mount Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Operating Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Component \/ Zero Idle Draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuppressor Technology\u003c\/td\u003e\n\u003ctd\u003eVaristor (MOV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e56 to 136 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e78 to 180 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDirect Contactor Coil Terminal Snap-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Network Protection and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eEngineered to prevent high-voltage electrical fast transients (EFT) from entering local control wiring, the module maintains signal integrity across dense control panels. By clamping inductive voltage spikes right at the source, it protects low-voltage I\/O density scaling architectures, preventing corruption of EtherNet\/IP deterministic networks and ensuring backplane bus communication velocity remains uninterrupted during high-frequency contactor switching routines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 100-FSV136 surge suppressor increase contactor drop-out time?\u003c\/p\u003e\n\u003cp\u003eA: Varistor-based surge suppressors like the 100-FSV136 clamp peak overshoot voltages while adding negligible delay (typically under a few milliseconds) to contactor release times compared to standard diode suppressors.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 100-FSV136 module be used on both AC and DC control circuits?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the integrated varistor network operates bidirectionally, supporting operating voltage ranges of 56 to 136 VAC (50\/60 Hz) and 78 to 180 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate all control power and main line voltage before accessing contactor coil terminals.\u003c\/li\u003e\n\u003cli\u003eSnap the 100-FSV136 module directly onto the front or top coil interface of the compatible Allen-Bradley contactor.\u003c\/li\u003e\n\u003cli\u003eEnsure the module terminal pins fully engage the contactor coil screw clamp terminals.\u003c\/li\u003e\n\u003cli\u003eTighten coil connection screws to the contactor manufacturer's recommended torque specifications.\u003c\/li\u003e\n\u003cli\u003eVerify that control wiring is clear of moving mechanical armatures before reapplying operating voltage.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52693170520344,"sku":"100-FSV136","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/100-FSV1362_Cocoai_f6785fa7-e730-441a-9f00-3fe0f0a672cc.jpg?v=1789612065","url":"https:\/\/www.innoplcsync.com\/products\/allen-bradley-100-fsv136-surge-suppressor-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}