{"product_id":"1746-no8v-allen-bradley-analog-voltage-output-module","title":"1746-NO8V | Allen-Bradley Analog Voltage Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1746-NO8V\u003c\/strong\u003e is an 8-channel analog voltage output module designed for the SLC 500 programmable controller platform. It provides voltage output signals for interfacing controller-generated analog commands with compatible field devices. The supplied product information identifies it as a rack-mounted module with a 24 VDC specification and confirms that the model has been discontinued by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1746-NO8V provides eight analog output channels using voltage signaling. Analog voltage outputs allow a programmable controller to transmit variable control references to compatible equipment, such as devices with voltage-command inputs.\u003c\/p\u003e\n\u003cp\u003eThe required output voltage range, channel resolution, accuracy, and electrical load limits are not specified in the supplied information. These values should be verified against the original manufacturer documentation before selecting the module for a control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is identified for use with the Allen-Bradley SLC 500 platform and is described as rack-mounted. Before replacement or installation, verify the existing rack configuration, module identification, backplane requirements, and field wiring against the applicable SLC 500 hardware documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Availability and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDiscontinued by manufacturer\u003c\/p\u003e\n\u003cp\u003eThe 1746-NO8V is identified as discontinued by its manufacturer. The supplied listing also states that the factory warranty does not apply and that a \u003cstrong\u003eRadwell 2-year warranty\u003c\/strong\u003e is included. This warranty statement applies to the supplied product listing, not to an Allen-Bradley factory warranty.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-NO8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Voltage Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eRack Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Specification\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many output channels does the Allen-Bradley 1746-NO8V provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1746-NO8V has eight analog voltage output channels for transmitting variable control signals to compatible external equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 1746-NO8V still manufactured by Allen-Bradley?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied product information identifies the 1746-NO8V as discontinued by the manufacturer. Replacement selection should account for the existing SLC 500 hardware configuration and application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1746-NO8V include a manufacturer warranty?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied listing states that the factory warranty does not apply and that a Radwell 2-year warranty is included. Confirm the warranty terms with the seller when purchasing.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eiguration, in which the output circuit switches the connected load toward the DC common reference. This arrangement requires compatible field wiring and a suitable external DC supply for the connected loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides 32 output points divided into two electrically organized groups of 16. Each output supports a continuous current of 0.50 A at 30 deg C, decreasing to 0.25 A at 60 deg C. The total continuous current per module is rated at 8 A, subject to the applicable operating conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-OV32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital DC Sinking Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital DC Sinking Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003e2 groups of 16 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5-50 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current at 30 deg C\u003c\/td\u003e\n\u003ctd\u003e0.50 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current at 60 deg C\u003c\/td\u003e\n\u003ctd\u003e0.25 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current per Module\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current per Point\u003c\/td\u003e\n\u003ctd\u003e1.0 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Repetition at 30 deg C\u003c\/td\u003e\n\u003ctd\u003eEvery 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Repetition at 60 deg C\u003c\/td\u003e\n\u003ctd\u003eEvery 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Delay, OFF-to-ON\u003c\/td\u003e\n\u003ctd\u003e0.1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Delay, ON-to-OFF\u003c\/td\u003e\n\u003ctd\u003e1.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e190 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Isolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation per Channel\u003c\/td\u003e\n\u003ctd\u003e0.172 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Output Protection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eOne-slot SLC 500 chassis installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Installation\u003c\/td\u003e\n\u003ctd\u003eLocal or Remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003e40-pin female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Options\u003c\/td\u003e\n\u003ctd\u003e1746-NC3; 1492-CABLExx with 1492-IFM40xx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.19 lbs (0.54 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN \/ UPC\u003c\/td\u003e\n\u003ctd\u003e10662468092910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 1746-OV32 and a sourcing output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1746-OV32 uses sinking output circuitry, which switches the output toward the DC common reference. A sourcing output module instead supplies positive voltage to the connected load. The field wiring and load connection arrangement must match the output configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1746-OV32 drive loads requiring 0.50 A continuously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Each output point supports 0.50 A at 30 deg C, but this rating decreases to 0.25 A at 60 deg C. The total continuous current for the module is rated at 8 A. Both the individual channel and total module limits must be observed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1746-OV32 provide built-in electronic output protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied specifications identify the module as having no electronic output protection. External circuit protection should be provided and selected according to the connected loads and wiring requirements.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53357242810648,"sku":"1746-NO8V","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1746-NIO4I2_Cocoai_1_0d7bb79b-1231-435c-889d-c2595d9160b8.jpg?v=1795141298","url":"https:\/\/www.innoplcsync.com\/products\/1746-no8v-allen-bradley-analog-voltage-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}