{"product_id":"foxboro-p0902ca-analog-input-module","title":"Foxboro|P0902CA|Modul Input Analog","description":"\u003cdiv class=\"qk-md-paragraph\"\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eModul Masukan Analog FOXBORO P0902CA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDeskripsi\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eFOXBORO P0902CA adalah modul masukan analog 16 saluran presisi tinggi yang dirancang untuk sistem kontrol proses industri, mendukung akuisisi sinyal 4–20 mA dengan isolasi dan diagnostik lanjutan.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eFitur\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003e• 16 saluran masukan analog 4–20 mA\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003e• Isolasi antar saluran dan lapangan\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003e• Indikasi status LED per saluran\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003e• Akurasi tinggi dan stabilitas termal\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003e• Dapat diganti panas saat operasi\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003e• Sepenuhnya kompatibel dengan FOXBORO I\/A Series DCS\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSpesifikasi Teknis\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eMasukan Sinyal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eRentang Masukan: 4–20 mA (standar), dapat dikonfigurasi\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eResolusi: 16-bit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eImpedansi Masukan: 250 Ω\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eAkurasi: ±0,1% dari skala penuh\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eDrift Suhu: ±0,01% FS\/°C\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eIsolasi \u0026 Perlindungan\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eTegangan Isolasi: 2500 V AC (saluran ke backplane)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePerlindungan Tegangan Lebih: Hingga 30 V DC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePenekanan Transien: Terintegrasi\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003ePerforma\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eKecepatan Sampling: 100 Hz per saluran\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eWaktu Respon: ≤ 1 ms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eLinearitas: ±0,05% FS\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"qk-md-paragraph\"\u003e\n\u003cstrong class=\"qk-md-strong complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eLingkungan\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"qk-md-ul\"\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eSuhu Operasi: -25°C hingga 70°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eKelembapan: 10–90% RH, tidak mengembun\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"qk-md-li complete\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eGetaran: 10–55 Hz, puncak 5g\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":51734000632088,"sku":"P0902CA","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/s-l960_1_bca9c683-3f75-4dfb-8d77-d81468c0d3e9.jpg?v=1730803319","url":"https:\/\/www.innoplcsync.com\/id\/products\/foxboro-p0902ca-analog-input-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}