Honeywell|10102/1/2|
HONEYWELL 10100/1/1 Horizontal Bus Driver (HBD) Module
Description
HONEYWELL 10100/1/1 is a Horizontal Bus Driver (HBD) module used in FSC systems to interface the processor with I/O modules via the vertical bus (V-Bus), enabling scan, test, and update functions.
Features
- Connects Central Part to I/O racks through V-Bus flatcable
- Used in non-redundant and redundant system configurations
- Supports integration with V-Bus guided through racks
- Compatible with VBD modules 10001/1/1 and 10001/R/1
- Enables I/O module communication without direct CPU connection
Technical Specifications
-
Approvals
CE, TÜV, UL listed -
Power Requirements
Supplied via backplane; power consumption included in system specification -
Mechanical & Installation
Space required: 84 TE (84 HP), 1 HE (1U) per full rack
Mounting: Standard 19-inch rack with dedicated backplane
V-Bus Interface: 34-wire flatcable connection
Integration Method: Type 1 – V-Bus routed through racks -
System Compatibility
Supports configurations with:- Non-redundant or redundant Central Parts
- Non-redundant or redundant I/O
- Up to 9 combined VBD and HBD connections per V-Bus
Required in systems using multiple 24 Vdc to 5 Vdc power supplies or when watchdog current exceeds 900 mA
Honeywell|10102/1/2|
HONEYWELL 10100/1/1 Horizontal Bus Driver (HBD) Module
Description
HONEYWELL 10100/1/1 is a Horizontal Bus Driver (HBD) module used in FSC systems to interface the processor with I/O modules via the vertical bus (V-Bus), enabling scan, test, and update functions.
Features
- Connects Central Part to I/O racks through V-Bus flatcable
- Used in non-redundant and redundant system configurations
- Supports integration with V-Bus guided through racks
- Compatible with VBD modules 10001/1/1 and 10001/R/1
- Enables I/O module communication without direct CPU connection
Technical Specifications
-
Approvals
CE, TÜV, UL listed -
Power Requirements
Supplied via backplane; power consumption included in system specification -
Mechanical & Installation
Space required: 84 TE (84 HP), 1 HE (1U) per full rack
Mounting: Standard 19-inch rack with dedicated backplane
V-Bus Interface: 34-wire flatcable connection
Integration Method: Type 1 – V-Bus routed through racks -
System Compatibility
Supports configurations with:- Non-redundant or redundant Central Parts
- Non-redundant or redundant I/O
- Up to 9 combined VBD and HBD connections per V-Bus
Required in systems using multiple 24 Vdc to 5 Vdc power supplies or when watchdog current exceeds 900 mA