Bently Nevada|3500/65 172109-01|16-Channel Temperature Monitor
Bently Nevada 3500/65 172109-01 16-Channel Temperature Monitor
Description
The Bently Nevada 3500/65 172109-01 is a 16-channel temperature monitor module supporting RTD and isolated tip thermocouple (TC) inputs for industrial machinery condition monitoring.
Key Features
- 16-channel input support for RTD and TC sensors
- Supports 3-wire/4-wire RTD and types E/J/K/T thermocouples
- Triple Modular Redundant (TMR) configuration support
- Software-configurable alarm setpoints and delay times
- Front-panel LED indicators for status (OK, TX/RX, Bypass)
- No calibration required
Technical Specifications
Inputs
Signal Types
-
RTDs:
- 100Ω platinum (α=0.00385/0.00392)
- 120Ω nickel
- 10Ω copper
- Measurement range: -200°C to +850°C
-
Thermocouples:
- Type E: -100°C to +1000°C
- Type J: 0°C to +760°C
- Type K: 0°C to +1370°C
- Type T: -160°C to +400°C
Electrical Characteristics
- Input impedance: >1 MΩ per lead
- RTD current source: 913 ±7 µA per transducer
Performance
- Resolution: 1°C / 1°F
- Accuracy: ±3°C at 25°C (±5.4°F at 77°F)
- Cold junction compensation accuracy: ±2°C at 25°C (±3.6°F at 77°F)
Alarms
- Setpoint range: 0–100% of full scale (accuracy: ±0.13% of setpoint)
- Alert delay: 1–60 seconds (1 sec steps)
- Danger delay: 1–60 seconds (0.5 sec steps), minimum 225 ms
Power & Physical Specifications
- Power consumption: 3 W nominal
- Dimensions: 241.3 × 24.4 × 241.8 mm (9.50 × 0.96 × 9.52 in)
- Weight: 0.45 kg (I/O module)
Bently Nevada|3500/65 172109-01|16-Channel Temperature Monitor



Bently Nevada|3500/65 172109-01|16-Channel Temperature Monitor
Bently Nevada 3500/65 172109-01 16-Channel Temperature Monitor
Description
The Bently Nevada 3500/65 172109-01 is a 16-channel temperature monitor module supporting RTD and isolated tip thermocouple (TC) inputs for industrial machinery condition monitoring.
Key Features
- 16-channel input support for RTD and TC sensors
- Supports 3-wire/4-wire RTD and types E/J/K/T thermocouples
- Triple Modular Redundant (TMR) configuration support
- Software-configurable alarm setpoints and delay times
- Front-panel LED indicators for status (OK, TX/RX, Bypass)
- No calibration required
Technical Specifications
Inputs
Signal Types
-
RTDs:
- 100Ω platinum (α=0.00385/0.00392)
- 120Ω nickel
- 10Ω copper
- Measurement range: -200°C to +850°C
-
Thermocouples:
- Type E: -100°C to +1000°C
- Type J: 0°C to +760°C
- Type K: 0°C to +1370°C
- Type T: -160°C to +400°C
Electrical Characteristics
- Input impedance: >1 MΩ per lead
- RTD current source: 913 ±7 µA per transducer
Performance
- Resolution: 1°C / 1°F
- Accuracy: ±3°C at 25°C (±5.4°F at 77°F)
- Cold junction compensation accuracy: ±2°C at 25°C (±3.6°F at 77°F)
Alarms
- Setpoint range: 0–100% of full scale (accuracy: ±0.13% of setpoint)
- Alert delay: 1–60 seconds (1 sec steps)
- Danger delay: 1–60 seconds (0.5 sec steps), minimum 225 ms
Power & Physical Specifications
- Power consumption: 3 W nominal
- Dimensions: 241.3 × 24.4 × 241.8 mm (9.50 × 0.96 × 9.52 in)
- Weight: 0.45 kg (I/O module)