Description
The BENTLY NEVADA 88984-01 is a 16-channel temperature monitoring module in the 3500 series that accepts RTD or thermocouple inputs to provide real-time temperature measurement and protection for industrial machinery.
The BENTLY NEVADA 88984-01 is a 16-channel temperature monitoring module in the 3500 series that accepts RTD or thermocouple inputs to provide real-time temperature measurement and protection for industrial machinery.
Features
- Supports RTD (Pt100) and Type J/K/T thermocouples
- Provides configurable alarm logic per channel
- Outputs 4–20 mA and relay signals
- Compatible with 3500 rack systems
Technical Specifications
- Input channels: 16 isolated differential inputs
- RTD type: Pt100 (IEC 60751), 2-/3-wire configurable
- Thermocouple types: J, K, T (selectable per channel)
- Measurement range: –200°C to +850°C (sensor-dependent)
- Accuracy: ±0.5°C for RTD; ±2.0°C for thermocouples
- Update rate: ≤500 ms per channel
- Analog output: 4–20 mA (scalable, isolated)
- Relay outputs: Optional via companion relay module
- Operating voltage: 24 VDC nominal (18–32 VDC)
- Power consumption: ≤10 W
- Operating temperature: –40°C to +70°C
- Storage temperature: –40°C to +85°C
- Humidity: 0–95% RH, non-condensing
- Dimensions: 132 mm × 102 mm × 25 mm
Bently Nevada|88984-01|Temperature Monitor Module
Current product
Current
Vendor:
BENTLY NEVADA
Bently Nevada|88984-01|Temperature Monitor Module
Regular price
$100.00
Sale price
$100.00
Regular price
$300.00
Options
Descriptions
BENTLY NEVADA 88984-01 Temperature Monitor Module
Description
The BENTLY NEVADA 88984-01 is a 16-channel temperature monitoring module in the 3500 series that accepts RTD or thermocouple inputs to provide real-time temperature measurement and protection for industrial machinery.
The BENTLY NEVADA 88984-01 is a 16-channel temperature monitoring module in the 3500 series that accepts RTD or thermocouple inputs to provide real-time temperature measurement and protection for industrial machinery.
Features
- Supports RTD (Pt100) and Type J/K/T thermocouples
- Provides configurable alarm logic per channel
- Outputs 4–20 mA and relay signals
- Compatible with 3500 rack systems
Technical Specifications
- Input channels: 16 isolated differential inputs
- RTD type: Pt100 (IEC 60751), 2-/3-wire configurable
- Thermocouple types: J, K, T (selectable per channel)
- Measurement range: –200°C to +850°C (sensor-dependent)
- Accuracy: ±0.5°C for RTD; ±2.0°C for thermocouples
- Update rate: ≤500 ms per channel
- Analog output: 4–20 mA (scalable, isolated)
- Relay outputs: Optional via companion relay module
- Operating voltage: 24 VDC nominal (18–32 VDC)
- Power consumption: ≤10 W
- Operating temperature: –40°C to +70°C
- Storage temperature: –40°C to +85°C
- Humidity: 0–95% RH, non-condensing
- Dimensions: 132 mm × 102 mm × 25 mm