BENTLY NEVADA 84508-32 is a 4-channel relay output module used in the 3500 machinery protection system to provide alarm and shutdown signals based on monitored conditions.
BENTLY NEVADA 84508-32 is a 4-channel relay output module used in the 3500 machinery protection system to provide alarm and shutdown signals based on monitored conditions.
Features
- Provides fail-safe relay outputs
- Supports alarm and trip functions
- Compatible with 3500 framework monitoring modules
Technical Specifications
- Module Type: 4-Channel Relay Output Module
- Relay Contact Rating: 2 A at 30 VDC or 250 VAC (resistive load)
- Contact Configuration: Normally open (NO) and normally closed (NC) per channel
- Operating Voltage Range: 18–32 VDC for logic circuitry
- Isolation Voltage: 2500 V RMS between field and logic circuits
- Response Time: Less than 10 ms from input trigger to contact closure
- Operating Temperature: 0°C to +65°C
- Storage Temperature: -40°C to +85°C
- Power Consumption: Approximately 3.5 watts
- Dimensions: Standard 3500 module size – 9.5 in H × 0.96 in W × 9.52 in D
- Mounting: Hot-swappable in any I/O slot of the 3500 chassis
Bently Nevada|84508-32|Relay Output Module
Current product
Current
Vendor:
BENTLY NEVADA
Bently Nevada|84508-32|Relay Output Module
Regular price
$205.00
Sale price
$205.00
Regular price
$430.00
Options
Descriptions
BENTLY NEVADA 84508-32 Relay Output Module
Description
BENTLY NEVADA 84508-32 is a 4-channel relay output module used in the 3500 machinery protection system to provide alarm and shutdown signals based on monitored conditions.
BENTLY NEVADA 84508-32 is a 4-channel relay output module used in the 3500 machinery protection system to provide alarm and shutdown signals based on monitored conditions.
Features
- Provides fail-safe relay outputs
- Supports alarm and trip functions
- Compatible with 3500 framework monitoring modules
Technical Specifications
- Module Type: 4-Channel Relay Output Module
- Relay Contact Rating: 2 A at 30 VDC or 250 VAC (resistive load)
- Contact Configuration: Normally open (NO) and normally closed (NC) per channel
- Operating Voltage Range: 18–32 VDC for logic circuitry
- Isolation Voltage: 2500 V RMS between field and logic circuits
- Response Time: Less than 10 ms from input trigger to contact closure
- Operating Temperature: 0°C to +65°C
- Storage Temperature: -40°C to +85°C
- Power Consumption: Approximately 3.5 watts
- Dimensions: Standard 3500 module size – 9.5 in H × 0.96 in W × 9.52 in D
- Mounting: Hot-swappable in any I/O slot of the 3500 chassis