BENTLY NEVADA 1034549-40 is a high-performance eddy-current proximity probe designed for precise measurement of displacement, vibration, and position in rotating machinery.
Features
- Non-contact measurement technology
- Compatible with 3300/3500 monitoring systems
- Rugged stainless steel construction
- High temperature and EMI resistance
Technical Specifications
- Probe Diameter: 8 mm (5/16 inch)
- Overall Length: 1.0 meter (standard cable length)
- Sensitivity: 7.87 mV/µm (200 mV/mil) nominal
- Measurement Range: 2.0 mm (80 mils) linear range
- Frequency Response: DC to 10 kHz (-3 dB)
- Operating Temperature: -51°C to +177°C (-60°F to +350°F)
- Tip Material: 300-series stainless steel
- Cable Type: Coaxial, mineral-insulated, stainless steel armored
- Connector: Standard MS-style or DIN options
- Compliance: Meets API 670 standards for machinery protection
- Linear Accuracy: ±0.25% of full scale typical
- Probe Resolution: Sub-micron level
Bently Nevada |1034549-40|Proximity Probe
Bently Nevada |1034549-40|Proximity Probe
BENTLY NEVADA 1034549-40 Proximity Probe
Description
BENTLY NEVADA 1034549-40 is a high-performance eddy-current proximity probe designed for precise measurement of displacement, vibration, and position in rotating machinery.
Features
- Non-contact measurement technology
- Compatible with 3300/3500 monitoring systems
- Rugged stainless steel construction
- High temperature and EMI resistance
Technical Specifications
- Probe Diameter: 8 mm (5/16 inch)
- Overall Length: 1.0 meter (standard cable length)
- Sensitivity: 7.87 mV/µm (200 mV/mil) nominal
- Measurement Range: 2.0 mm (80 mils) linear range
- Frequency Response: DC to 10 kHz (-3 dB)
- Operating Temperature: -51°C to +177°C (-60°F to +350°F)
- Tip Material: 300-series stainless steel
- Cable Type: Coaxial, mineral-insulated, stainless steel armored
- Connector: Standard MS-style or DIN options
- Compliance: Meets API 670 standards for machinery protection
- Linear Accuracy: ±0.25% of full scale typical
- Probe Resolution: Sub-micron level