NTRL03 | ABB | Bailey Termination Module
Overview
The ABB NTRL03 is a robust and reliable module designed for industrial automation systems. It facilitates data communication and power supply within the Bailey INFI 90 system, ensuring stable and efficient operation.
Technical Specifications
| Specification | Details |
|---|---|
| Manufacturer: | ABB |
| Model: | NTRL03 |
| Category: | Industrial Automation |
| Input Voltage: | +24 VDC (118 mA maximum) from the 24 VDC bus |
| Inputs: | Communication link from another TRL termination unit |
| Station serial communication link | |
| Fiber Optic Receiver Signal Limits (NTRL02 only): -30 dBm minimum, -10 dBm maximum | |
| Outputs: | Communication link to another termination unit |
| Station serial communication link | |
| 24 VDC power to attached stations | |
| Cable Insulation Specifications: | PVC (UL Rating CL2): 80°C (176°F) at 300 V |
| Non-PVC (UL Rating PLTC): 90°C (194°F) at 300 V | |
| Mounting: | Occupies one space in a standard INFI 90 field termination panel |
| Electromagnetic/Radio Frequency Interference: | Keep the cabinet doors closed. Do not use communication equipment any closer than 2 m from the cabinet. |
| Ambient Temperature: | 0° to 70°C (32° to 158°F) |
| Relative Humidity: | 0% to 95% up to 55°C (131°F) (non-condensing) |
| 0% to 45% up to 70°C (158°F) (non-condensing) |
NTRL03 | ABB | Bailey Termination Module
NTRL03 | ABB | Bailey Termination Module
Overview
The ABB NTRL03 is a robust and reliable module designed for industrial automation systems. It facilitates data communication and power supply within the Bailey INFI 90 system, ensuring stable and efficient operation.
Technical Specifications
| Specification | Details |
|---|---|
| Manufacturer: | ABB |
| Model: | NTRL03 |
| Category: | Industrial Automation |
| Input Voltage: | +24 VDC (118 mA maximum) from the 24 VDC bus |
| Inputs: | Communication link from another TRL termination unit |
| Station serial communication link | |
| Fiber Optic Receiver Signal Limits (NTRL02 only): -30 dBm minimum, -10 dBm maximum | |
| Outputs: | Communication link to another termination unit |
| Station serial communication link | |
| 24 VDC power to attached stations | |
| Cable Insulation Specifications: | PVC (UL Rating CL2): 80°C (176°F) at 300 V |
| Non-PVC (UL Rating PLTC): 90°C (194°F) at 300 V | |
| Mounting: | Occupies one space in a standard INFI 90 field termination panel |
| Electromagnetic/Radio Frequency Interference: | Keep the cabinet doors closed. Do not use communication equipment any closer than 2 m from the cabinet. |
| Ambient Temperature: | 0° to 70°C (32° to 158°F) |
| Relative Humidity: | 0% to 95% up to 55°C (131°F) (non-condensing) |
| 0% to 45% up to 70°C (158°F) (non-condensing) |