Woodward|8408-921|Single Channel Exciter

SKU: 8408-921
  • Manufacturer: Woodward

  • Product No.: 8408-921

  • Condition:في الأوراق المالية

  • Product Type: Single Channel Exciter

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Woodward 8408-921 Single Channel Exciter for Industrial Gas Turbine Ignition System

Description

The Woodward 8408-921 is a single-channel STExcite™ high-energy ignition driver designed for industrial gas turbines, interfacing with ignition leads and igniters to generate high-current ignition pulses for combustion chamber ignition.

Features

  • Digital Signal Processing (DSP): Enables advanced diagnostics, self-testing, and fault detection for reliable operation.
  • Drop-In Replacement: Designed to directly replace existing ignition system drivers in legacy turbine setups.
  • Wide Compatibility: Works with industry-standard igniters and flexible ignition leads (3.0 m to 9.8 m).
  • Safety & Monitoring: Internal fault relay and alarm contact to signal power loss, voltage issues, or ignition failures.
  • Communication Capability: Supports DeviceNet for network integration and remote diagnostics.
  • Hazardous Environment Compliance: Available with CSA certification for Class I, Division 2, Group D locations and CE marking for EMC/Low Voltage directives.

Technical Specifications

  • Input Power:
    • Single Channel (8408-921):
      • 115 V~ 60 Hz (75 VA max., CSA listed for US/Canada).
      • 115 V~ 50/60 Hz (75 VA max., CE marked).
  • Spark Rate: 1.8 ±0.1 sparks/second.
  • Output Characteristics:
    • Open Circuit Voltage: 15–20 kV.
    • Typical Igniter Voltage: < 8 kV.
    • Energy:
      • 2 J minimum (3.0 m leads); 1.5 J minimum (9.8 m leads).
    • Energy Duration: 50 µs.
    • Peak Power: 50,000 W minimum.
    • Peak Current: 1,200 A minimum.
  • Environmental Specifications:
    • Operating Temperature: -20°C to +55°C (-4°F to +131°F).
    • Storage Temperature: Not explicitly listed (refer to manufacturer guidelines).
  • Diagnostic Output:
    • Normally open relay output (125 Vdc, 0.3 A) for fault indication.
  • Regulatory Compliance:
    • CE Marking: EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC.
    • CSA Certification: Class I, Division 2, Group D, T4A (85°C ambient, for US/Canada).
  • Physical Design:
    • Output Channels: Single channel (paired with STExcite 2010 for dual-channel systems).
    • Included Components: All ignition leads, cables, and diagnostic relay for complete system integration.
معلومات الطلب والضمان

شروط الشراء والإرجاع

إرشادات مفصلة حول الحد الأدنى لكمية الطلب ومواعيد التسليم وخيارات الدفع والضمان وسياسات الإرجاع.

نحن نقبل بكل سرور الطلبات بالجملة، مع الحد الأدنى لكمية الطلب وهو وحدة واحدة فقط.

عند الطلب، يمكننا تقديم جميع المستندات اللازمة، بما في ذلك شهادات المنشأ/المطابقة وغيرها من أوراق التصدير المطلوبة.

نحن نقبل الدفع بنسبة 100% T/T (التحويل البرقي) قبل الشحن. بالنسبة للعناصر التي تتطلب مهلة زمنية، يلزم إيداع 30% مقدمًا، مع دفع 70% المتبقية قبل الشحن. بالنسبة للتحويلات بالرنمينبي، يرجى الاتصال بنا إذا كان لديك وكيل في الصين.

جميع العناصر الجديدة والأصلية تأتي مع ضمان قياسي لمدة عام واحد. للحصول على خيارات الضمان الممتد، لا تتردد في الاتصال بنا للحصول على تفاصيل التسعير.

نحن نعطي الأولوية لرضاك. إذا كنت بحاجة إلى إرجاع منتج ما، فيجب أن يتم ذلك خلال 30 يومًا من تاريخ الشراء. يجب أن يكون المنتج غير مستخدم، وغير مفتوح، وفي عبوته الأصلية، بما في ذلك جميع الملحقات. ستتم معالجة المبالغ المستردة خلال 5-7 أيام عمل من استلام المرتجع. يرجى ملاحظة أن رسوم الشحن والمناولة غير قابلة للاسترداد.

مقارنة السلعة